Certification
6.1.11 RoHS
6.1.11
RoHS
This device is declared by Siemens Canada Ltd. to meet the requirements of the
following RoHS (Restriction of Hazardous Substances) directives for the restricted use
of certain hazardous substances in electrical and electronic equipment:
•
China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic
Information Products
A copy of the Material Declaration is available online at
support.industry.siemens.com/cs/ww/en/view/109738831
.
6.1.12
Other Approvals
This device meets the requirements of the following additional standards:
•
IEC 61000-6-2
Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity
for Industrial Environments
•
EN 50121-4
Railway applications – Electromagnetic Compatibility – Emission and Immunity
of the Signaling and Telecommunications Apparatus
•
EN 50121-3-2
Railway applications – Electromagnetic Compatibility – Rolling Stock Apparatus
•
EN 50155
Railway applications – Rolling stock – Electronic equipment
6.2
EMC and Environmental Type Tests
The RUGGEDCOM RSG910C has passed the following Electromagnetic Compatibility
(EMC) and environmental tests.
EMC Type Tests
Test
Description
Test Levels
Severity
Levels
Enclosure
Contact
± 8 kV
4
IEC
61000-4-2
ESD
Enclosure Air
± 15 kV
4
IEC
61000-4-3
Radiated RFI
Enclosure
Ports
20 V/m
Signal Ports
± 4 kV @ 2.5 kHz, 5 kHz
4
IEC
61000-4-4
Burst (Fast Transient)
DC Power
Ports
± 4 kV @ 2.5 kHz, 5 kHz
4
36
RUGGEDCOM RSG910C