Chapter 2
Installing Device
RUGGEDCOM RSG2300
Installation Guide
16
Grounding the Device
1
3
2
Figure 12: Failsafe Alarm Relay Wiring
1.
Normally Open
2.
Common
3.
Normally Closed
Section 2.4
Grounding the Device
The RUGGEDCOM RSG2300 chassis ground terminal uses a #6-32 screw. It is recommended to terminate the
ground connection with a #6 ring lug and torque it to 1.7 N·m (15 lbf·in).
2
1
3
Figure 13: Chassis Ground Connection
1.
Stainless Steel Stud
2.
#6-32 Screw
3.
#6 Ring Lug
Section 2.5
Connecting to the Device
The following describes the various methods for accessing the ROS console and Web interfaces on the device.
For more detailed instructions, refer to the
ROS User Guide
for the RUGGEDCOM RSG2300.