RUGGEDCOM RSG2300
Installation Guide
Chapter 2
Installing Device
Connecting Power
9
2
1
1
Figure 4: Panel Mounting
1.
Screw
2.
Panel/DIN Rail Adapter
2. Install the supplied screws to secure the adapters to the panel.
Section 2.2
Connecting Power
The RUGGEDCOM RSG2300 supports a single or dual redundant AC and/or DC power supplies. The use of two
power modules is recommended to provide redundancy and load balancing.
The RUGGEDCOM RSG2300 can be equipped with either a screw-type or pluggable terminal block, which
provides power to both power supplies. The screw-type terminal block is installed using Phillips screws and
compression plates, allowing either bare wire connections or crimped terminal lugs. Use #6 size ring lugs for
secure, reliable connections under severe shock or vibration.
CAUTION!
Electrical hazard – risk of damage to the device. Disconnect the device from the power supply if power
input is above or below the specified input range. For more information, refer to
.
NOTE
• For maximum redundancy in a dual power supply configuration, use two independent power
sources.