Technical Specifications
Fiber Optic Ethernet Port Specifications
27
Cable Type
f
> CAT 5
Wiring Standard
g
TIA/EIA T568A/B
Maximum Distance
h
100 m (328 ft)
Isolation
i
2.5 kV
e
Auto-negotiating.
f
Shielded or unshielded.
g
Auto-crossover and auto-polarity.
h
Typical distance. Dependent on the number of connectors and splices.
i
RMS 1 minute.
Section 5.4
Fiber Optic Ethernet Port Specifications
The following details the specifications for fiber Ethernet ports that can be ordered with the RUGGEDCOM RS900F.
NOTE
• All optical power numbers are listed as dBm averages. To convert from average to peak, add 3 dBm.
To convert from peak to average, subtract 3 dBm.
• Maximum segment length is greatly dependent on factors such as fiber quality, and the number
of patches and splices. Consult a Siemens sales associate when determining maximum segment
distances.
Tx (dBm)
Mode
Connector
Type
Tx λ (nm)
j
Cable
Type (μm)
Minimum
Maximum
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(km)
j
Power
Budget
(dB)
50/125
-22.5
-14
-33.5
-14
2
11
MM
MTRJ
1300
62.5/125
-19
-14
-33.5
-14
2
14.5
50/125
-22.5
-14
-33.9
-14
2
11.4
MM
SC
1300
62.5/125
-19
-14
-33.9
-14
2
14.9
50/125
-22.5
-14
-33.9
-14
2
11.4
MM
ST
1300
62.5/125
-19
-14
-33.9
-14
2
14.9
MM
LC
1310
62.5/125
-19
-14
-32
-14
2
13
SM
ST
1310
9/125
-15
-7
-34
-3
20
19
SM
LC
1300
9/125
-15
-8
-38
-3
20
23
SM
LC
1310
9/125
-5
0
-35
-3
50
30
SM
LC
1310
9/125
0
5
-37
0
90
37
SM
SC
1300
9/125
-15
-8
-31
-7
20
16
SM
SC
1310
9/125
-5
0
-34
-3
50
29
SM
SC
1310
9/125
5
0
-37
0
90
42
j
Typical.