Chapter 3
Device Management
RUGGEDCOM ROS
User Guide
70
Configuring Link Detection
5
6
4
3
2
1
Figure 29: Port Mirroring Form
1.
Port Mirroring Box
2.
Source Port Box
3.
Target Port Box
4.
Apply Button
5.
Reload Button
2. Configure the following parameter(s) as required:
Parameter
Description
Port Mirroring
Synopsis:
{ Disabled, Enabled }
Default:
Disabled
Enabling port mirroring causes all frames received and transmitted by the source port(s)
to be transmitted out of the target port.
Source Port
Synopsis:
Any combination of numbers valid for this parameter
The port(s) being monitored.
Source Direction
Synopsis:
Egress and Ingress, Egress Only
Default:
Egress and Ingress
Specifies monitoring whether both egress and ingress traffics or only egress traffic of the
source port.
Target Port
Synopsis:
1 to maximum port number
Default:
1
The port where a monitoring device should be connected.
3. Click
Apply
.
Section 3.6.10
Configuring Link Detection
To configure link detection, do the following:
1. Navigate to
Ethernet Ports
»
Configure Link Detection
. The
Link Detection
form appears.