Chapter 3
Device Management
RUGGEDCOM ROS
User Guide
62
Clearing Statistics for Specific Ethernet Ports
Parameter
Description
The number of received and transmitted packets with size of 1024 to 1536 octets. This
includes received and transmitted packets as well as dropped and local received packets.
This does not include rejected received packets.
DropEvents
Synopsis:
0 to 4294967295
The number of received packets that are droped due to lack of receive buffers.
OutMulticasts
Synopsis:
0 to 18446744073709551615
The number of transmitted Multicast packets. This does not include Broadcast packets.
OutBroadcasts
Synopsis:
0 to 18446744073709551615
The number of transmitted Broadcast packets.
UndersizePkts
Synopsis:
0 to 4294967295
The number of received packets which meet all the following conditions:
• Packet data length is less than 64 octets.
• Collision Event has not been detected.
• Late Collision Event has not been detected.
• Packet has valid CRC.
Section 3.6.5
Clearing Statistics for Specific Ethernet Ports
To clear the statistics collected for one or more Ethernet ports, do the following:
1. Navigate to
Ethernet Stats
»
Clear Ethernet Port Statistics
. The
Clear Ethernet Port Statistics
form
appears.
1
2
Figure 24: Clear Ethernet Port Statistics Form (Typical)
1.
Port Check Boxes
2.
Confirm Button
2. Select one or more Ethernet ports.
3. Click
Confirm
.
Section 3.6.6
Managing SFP Transceivers
ROS supports Small Form Factor Pluggable (SFP) transceivers to provide a 1000Base-X, 100Base-FX,
1000Base-T or 100Base-TX link.