Siemens QAA2391.EWTC Installation Instructions Download Page 1

 

 

Installation Instructions 

Document No. 563-066 

November 2, 2015 

 

Wireless Room Sensor (WRS) 

 

 

Item Number 563-066, Rev. DA

 

 

Page 1 of 4 

 

Figure 1.  Wireless Room Sensor (Full-Featured). 

Product Description 

Wireless Room Sensors eliminate the need to run 
wire between Terminal Equipment Controllers 
(TECs) and their respective room temperature 
sensor. The sensor communicates wirelessly with 
the TEC using a Room Sensor Transceiver (RSX) 
mounted at the TEC. 

Product Numbers 

TALON

®

 Logo 

QAA2391.EWTC 

Wireless Room Sensor (WRS) – 
Sensing only 

QAA2391.DWTC 

Wireless Room Sensor (WRS) – 
Sensing with temperature 
display 

QAA2391.FWTC 

Wireless Room Sensor (WRS) – 
Sensing with override, setpoint, 
and temperature display 

No Logo 

QAA2391.EWNC 

Wireless Room Sensor (WRS) – 
Sensing only 

QAA2391.DWNC 

Wireless Room Sensor (WRS) – 
Sensing with temperature 
display 

QAA2391.FWNC 

Wireless Room Sensor (WRS) – 
Sensing with override, setpoint, 
and temperature display 

Accessories 

563-207 

Auto-binding cable (to bind 
WRS/RSX pair) 

544-643A 

RTS passkey (to change display to 
DIAG mode) 

N/A 

Replacement 3.6 Volts lithium AA 
battery –SAFT Part Number 
LS14500BA (See 

Field Purchasing 

Guide.

540-143 

Laptop computer cable 
(RJ-11 to DB-9) 

141-570 

Lockable Thermostat Guard, 
vented clear plastic. 

Related Products 

563-069 

Room Sensor Transceiver (RSX) 

563-007 

Direct Mount Antenna (for RSX) 

563-008 

Remote Mount Antenna (for RSX) 

563-210-01 

RSX/TEC Connection Cable (3 ft) 

563-210-02 

RSX/TEC Connection Cable (10 ft) 

Expected Installation Time 

10 minutes 

Caution Notations 

CAUTION: 

 

Equipment damage or loss of 
data may occur if you do not 
follow a procedure as 
specified. 

Prerequisite 

Install the associated transceiver per the 

Room 

Sensor Transceiver (RSX) Installation Instructions

 

(563-067). 

Summary of Contents for QAA2391.EWTC

Page 1: ...DWNC Wireless Room Sensor WRS Sensing with temperature display QAA2391 FWNC Wireless Room Sensor WRS Sensing with override setpoint and temperature display Accessories 563 207 Auto binding cable to bind WRS RSX pair 544 643A RTS passkey to change display to DIAG mode N A Replacement 3 6 Volts lithium AA battery SAFT Part Number LS14500BA See Field Purchasing Guide 540 143 Laptop computer cable RJ ...

Page 2: ...the auto binding cable Binding Using HMI Commands To bind your WRS to its associated RSX using HMI commands follow these steps 1 Connect a PC cable 540 143 from a computer to the RJ 11 port on the bottom of the WRS 2 Start a HyperTerminal session log on 1200 baud 8 data bits no parity 1 stop bit no flow control and then press ENTER to display the WRS prompt 3 At the WRS HMI prompt type BIND RSX a ...

Page 3: ...he base one or two revolutions to lock the cover to the base Be careful not to loosen too far as the screw can be completely removed from the base NOTE There is a perforated label containing the 16 digit EUID number on the back of the WRS It can be removed and placed on a schedule to facilitate future commissioning of a replacement WRS device if required Drywall Base Plate Mounting Figure 2 1 Usin...

Page 4: ...r installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit...

Reviews: