Siemens POL903.00/100 Manual Download Page 1

 
 
 
CC1N7219en 
10/28/2020 

 Smart 

Infrastructure 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WLAN stick 

POL903.00/100

 

 

 

 

 

 
Temporary WLAN interface for POS controllers, POL controllers, and DXR 
controllers during commissioning and service. Allows the controller to be 
configured and programmed via smartphone or tablet. 
Apps such as Climatix smart HMI or ABTGo cut down on programming time, 
configuration time, and commissioning time. 
 
The POL903.00/100 and this Data Sheet are intended for original equipment 
manufacturers (OEMs) using the POL903.00/100 in or on their products. 
 

Use 

The POL903.00/100 can be used with all Siemens controllers that have a compatible 
USB interface. 
 
The following Siemens controllers with a compatible USB interface are available: 
 
Type 

Data sheet 

Climatix C400 

A6V11276159 

Climatix C600 

A6V10990076 

Climatix S300 

A6V11417931 

Actuating DXR1 

A6V11393935, A6V11393929, A6V11393931, A6V11393933 

 
The respective data sheets clearly define the controller versions that are compatible 
with POL903.00/100. 
 

 

 

 

 

Summary of Contents for POL903.00/100

Page 1: ...POL903 00 100 and this Data Sheet are intended for original equipment manufacturers OEMs using the POL903 00 100 in or on their products Use The POL903 00 100 can be used with all Siemens controllers that have a compatible USB interface The following Siemens controllers with a compatible USB interface are available Type Data sheet Climatix C400 A6V11276159 Climatix C600 A6V10990076 Climatix S300 A...

Page 2: ...on and damp environments If such conditions do occur ensure that the POL903 00 100 is completely dry before reconnecting the power supply Electrostatic charges must be avoided since they can damage the electronic components of the POL903 00 100 on contact The WLAN stick is only intended for use with the controllers listed in this data sheet and is not designed to function as a standard WLAN stick ...

Page 3: ...pment Emission Requirements KDB 447498 D01 EN 55024 A1 EN 55032 Evaluation of electrical and electronic equipment in relation to restricting human exposure to electromagnetic fields 0 Hz to 300 GHz EN 62311 Federal Communications Commission Operation within the bandwidths of 902 928 MHz 2400 2483 5 MHz and 5725 5850 MHz FCC Part 15 Subpart C 15 247 USA and RSS 210 Issue 8 CAN Information technolog...

Page 4: ...r television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the...

Page 5: ...einafter referred to as the linked product and the relevant LGPL license criteria are met you may also i edit the linked product for your own use and in particular obtain the right to edit the linked product to link it to a modified version of the LGPL licensed module and ii reverse engineer the linked product but only for the purpose of correcting errors in your edits The right to edit does not i...

Page 6: ... 60721 3 1 Climatic conditions Class 1K3 Mechanical conditions Class 1M2 Temperature range 40 C to 60 C Humidity 90 r h non condensing Transport DIN EN 60068 2 and EN 60721 3 2 Climatic conditions Class 2K2 Mechanical conditions Class 2M2 Temperature range 40 C to 80 C Humidity 5 to 90 r h non condensing Operation DIN EN 60721 3 3 Climatic conditions Class 3K3 Mechanical conditions Class 3M2 Tempe...

Page 7: ...tick Password for the terminal unit SIBPAdmin DNS name siemens wlanstick Siemens AG recommends changing the password as part of the commissioning process Changes to all settings can be made via the web interface as required Connecting with the web interface for configuration The IP address is issued automatically via DHCP The default IP address of the WLAN stick is 10 123 45 1 The WLAN stick has a...

Page 8: ... are made in the Access Point tab Channel Channel for the WLAN network Network Name SSID SSID for the WLAN network Security Mode The chosen WLAN encryption technology SSID Mode Encryption of the SSID The WLAN password can be changed in the Password tab The IP DHCP tab includes details of the current network settings such as IP address Subnet mask Gateway DNS server The IP DHCP tab contains the set...

Page 9: ... Browse files or Drag Drop it here field Click in the Browse files or Drag Drop it here field and select the firmware file from your PC Click on the Update button to update the file Connecting with the web interface of a connected controller When using a Climatix controller the web interface of the controller can be accessed directly The web interface URL http 10 123 45 1 is directly available in ...

Page 10: ... be connected to the controller as shown in the following figures Note Cable length between POL903 00 100 WLAN stick and controller If the POL903 00 100 WLAN stick is not connected to the controller by a cable rather than being inserted directly the cable must be shielded and no longer than 2 5 meters ...

Page 11: ...11 11 Smart Infrastructure CC1N7219en 10 28 2020 Dimensions Dimensions in mm POL903 00 100 2020 Siemens Switzerland Ltd Theilerstrasse 1a 6300 Zug Switzerland Subject to change ...

Reviews: