Person-Machine Interface

Installation Instructions
Models PMI-2

INTRODUCTION

The Model PMI-2 from Siemens Industry, Inc., is the user interface for the FireFinder-
XLS™ system. From the PMI-2 the operator can acknowledge events, control the
system notification appliance circuits and reset the system. Detailed information
about the nature and location of events can also be displayed.

The PMI-2 is used as the primary user interface in CAB1, CAB2 or CAB3
enclosures. The PMI-2 can also be used as a primary user interface in a
remote REMBOX2 or REMBOX4 enclosure.

The PMI-2 contains the site specific program as developed in Zeus. All
system logic and supervision is provided by the controller in the PMI-2.

The PMI-2 contains a full VGA LCD, Touch Screen and LEDs for display-
ing system status. An audible sounds when there are unacknowledged
events on the PMI-2. The display is surrounded by keys that are used to
control the displayed information and to navigate through these
screens. Keys are also provided to obtain help and to enter into the
menu features of the PMI-2. (Refer to Figure 1.)

On the back of the PMI-2 there are additional diagnostic displays to aid
in system troubleshooting. This is also where the PMI-2 address is set
and where the connection is made to Zeus for programming. (Refer to
Figure 2.)

For systems configured to provide Smoke Control (UUKL), refer to the
FireFinder XLS Control Panel System Manual, P/N 315-034853.

PRE-INSTALLATION

Additional labels are available for applications that require French (Canadian), Spanish,
or Portuguese (Brazilian) languages. These labels need to be ordered separately.
Refer to the table below for ordering information.

To apply labels, remove the backing from the labels and apply them to the PMI-2.
(Refer to Figure 3.)

Summary of Contents for PMI-2

Page 1: ... PMI 2 contains the site specific program as developed in Zeus All system logic and supervision is provided by the controller in the PMI 2 The PMI 2 contains a full VGA LCD Touch Screen and LEDs for display ing system status An audible sounds when there are unacknowledged events on the PMI 2 The display is surrounded by keys that are used to control the displayed information and to navigate throug...

Page 2: ...a b d n a e s a b a t a d 2 D S I M P G w o l l a o t d e s u t r o p d r a c D S y t i l i b a p a c S U T A T S l a m r o n e t a c i d n i o t t h g i l s t n e m g e s g n i k l a W n a f i d e y a l p s i d s i e d o c r o r r E n o i t a r e p o d e t c e t e d s i D I r o r r e l a n r e t n i 5 C C O T 5 C C o t e l b a c n o b b i r n i p 0 6 s t c e n n o C M V L O T s u b o i d u a g o ...

Page 3: ... o i t p O 4 S n o g n i t t e s o N t i g i d o w t e h t o t s s e r d d a e d o n T E N X e h t t e S s u e Z n i t i r o f d e n g i s s a s s e r d d a N O o t 4 n o i t i s o p h c t i w s s n o i t p O 7 1 S t e S t i g i d e e r h t e h t o t s s e r d d a e d o n T E N X e h t t e S s u e Z n i t i r o f d e n g i s s a s s e r d d a s u e Z n i g n i t t e S m o r f s s e r d d a e d o n...

Page 4: ...he local audible Once all events are acknowl edged a reset button becomes available in the lower right side of the display If notification appliances were active two additional buttons appear at the bottom of the screen These allow the operator to silence or unsilence the notification appli ances When the notification appliances are silenced the Audibles Silenced LED lights The system can only be ...

Page 5: ...he Zeus tool replace the PMI with the new PMI 2 Please make sure you are converting the correct PMI with a PMI 2 by matching the address of the switches on the back of the PMI a In the configuration which you have just removed from the original PMI click on the PMI module in the physical tree Select the Edit menu and click on Find ReplaceTree Node A dialog box will open and allow you to replace th...

Page 6: ... into the project directory ii Once you have begun the transfer theTransfer Progress dialog displays transfer progress and status messages and allows you to cancel the transfer When you click OK at the transfer complete message the control panel will reset itself with the new configuration ELECTRICAL RATINGS r e w o P t u p n I r e w o P t u p t u O t n e r r u C e n a l P k c a B V 4 2 A m 5 9 1 ...

Reviews: