Operation
6
ATEX version gearboxes
The difference between the temperature of the housing and the ambient
temperature of max. +40° C must not exceed 70 K.
Using a suitable temperature sensor, measure the temperature at the lowest point
of the housing (oil sump) or at the mounting surface in the case of output units.
Changes are an indication of possible incipient damage.
CAUTION
Malfunctions can cause personal injuries or gearbox damage
In the event of changes during operation, the drive unit must be switched off immediately.
Determine the cause of the fault using the fault table (Page 53). Remedy faults or have
faults remedied.
Check the gear unit during operation for:
●
Excessive operating temperature
●
Changes in gear noise
●
Possible oil leakage at the housing and shaft seals