5.2
Without entry/exit monitoring
EAKO = ’1’
Schematic layout:
ÉÉÉÉÉ
ÉÉÉÉÉ
ÉÉÉÉÉ
ÉÉÉÉÉ
ÉÉÉÉÉ
ÉÉ
ÉÉ
ÉÉ
Prox. switch I
Direction of
movement of
MDS
MDS
Prox. switch II
ÉÉ
ÉÉ
ÉÉ
Computer
or PC
ASM 421
SLG
Dig. input
ANW
In this mode of operation, the user must ensure (e.g.using proximity switch I) that an MDS is guaranteed to
be present in the transmission window of the SLG before an MDS command is sent to the ASM. Any com-
mand now sent to the ASM will be executed immediately. If the ASM 421 does not find an MDS (presence
bit = 0), the command will immediately be terminated with an error. This also occurs if the MDS is defec-
tive. No NEXT command is required when MDS processing is complete. The computer is responsible for
controlling the entry and exit of the MDS.
Proximity switch II at the exit point is not absolutely necessary. The notification that an MDS has left the
transmission window is provided by the ASM 421 through the ANW bit and/or the Z message.