ASM 421 Technical Description
6GT2 097-3AH00-0DA2
– 37 –
RD: 03/02
6GT2 002-0DA00
ASM 421 / V.24
Subject to change without notice!
6GT2 002-0DB00
ASM 421 / RS422
6GT2 002-0DC00
ASM 421 / TTY
J31069-D0142-U001-A0-7618
3.4.10
MDS STATUS
Telegram to the file handler
’F’
CC CI
ADB
DBN DBL
xx
00
0000
0001
0
1
2/3
4
5
6/7
8/9
10
0001
00
’I’
Acknowledgement:
’F’
CC
Sta-
ADB DBN DBL
00 xx 0000
0001
16
Vol.
0
1
2/3
4
5
6/7
8/9
10
11/18
20/22
23/25
26/27
Indication (binary):
ECC corrections:
counts number of ECC
corrections performed:
only valid when working
with ECC
No. of times processed:
this counter has a width of 24
bits. It is incremented by 1 at
each SLG station before being
processed for the first time.
00
0001
28
29/31
Type
Free DIR entries:
Current count of free directory entries. This
number of further files can be opened.
(16 bits/hex).
Current free capacity:
Free or not yet reserved memory capacity on the MDS
(24 bits/hex)
MDS capacity:
Max. size of the user data area in the MDS in bytes (24 bits/hex)
Free cap.
DIR
Ind.
BZ
ECC
19
32
7
6
5
4
3
2
1
0
res.
res.
Aux. battery
(only for MDS 507 )
0 = OK
1 = poor
Support battery
0 = OK
1 = poor
This bit is always set
for MDS types with
EEPROM
MDS type:
The MDS was formatted with this MDS type by the FORMAT command (see sec-
tion 3.4.1) (1 byte/hex)
Volume:
Name of MDS; 8 ASCII characters (20H-7EH); the name was assigned during FORMAT.
Tot.cap.
0 = MDS is not protected.
1 = MDS is protected (by COVER
command).
tus