MOBY Commands
4-8
FC 56
J31069-D0155-U001-A0-7618
4.2
Parameterizing the Commands
4.2.1
FORMAT
Parameterizing the command in Command_DB
Table 4-3
UDT 50 “MOBY FH CMD” – FORMAT
Address
Name
Starting
Value
Commentary
0.0
+0.0
UID
DW#16#0
MDS number, only MOBY U with multitag
+4.0
command
’I’
MDS command: I = Format
+5.0
sub_command_1
B#16#0
MDS type
1
04H
05H
06H
2 kbytes
8 kbytes
32 kbytes
+6.0
sub_command_2
B#16#0
Option. The option is bit-coded. Several bits
can be used as shown in the following table.
0000xxx0B
0000xxx1B
0000xx0xB
0000xx1xB
0000x0xxB
0000x1xxB
00000xxxB
00001xxxB
Always read dir FAT
Checksum routine on (see chap. 1.2.3)
Entire MDS is deleted.
Directory and FAT are retained. User data area is
deleted.
2
Entire MDS is deleted.
Directory and FAT are deleted. User data area is
retained.
Normal
The counters for write cycles or ECC offsets are
retained. The counters are also retained even
when the system area is faulty (e.g., ECC error).
+7.0
sub_command_3
B#16#0
Not used
+8.0
Filename
’TEST-MDS’
MDS name
Character and/or digit combination in ASCII format (8 characters,
20H to 7EH). Can be selected as desired as data storage identi-
fier (is assigned to the MDS).
+16.0
length
L#1
Not used
+20.0
address_MDS
W#16#0
Not used
+22.0
DAT_DB_number
48
Not used
+24.0
DAT_DB_address
0
Not used
+26.0
QUEUE_DB_number
48
Not used
+28.0
QUEUE_DB_address
0
Not used
=30.0
1
The ECC mode which used to be transferred in earlier filehandler versions with the MDS type parameter,
is now set in UDT 10 under ECC_mode.
2 The internal filehandler dir FAT is always used for the formatting. This means that, before the
FORMAT command is even started, the dir FAT to be formatted can be transferred with the LOAD
command to the filehandler.
Acknowledgment data in the FORMAT command
The FORMAT command does not generate user data in the acknowledgment.
Summary of Contents for MOBY FC 56
Page 12: ...Introduction 1 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 63: ...5 1 FC 56 J31069 D0155 U001 A0 7618 Sample Applications 5 ...
Page 80: ...Sample Applications 5 18 FC 56 J31069 D0155 U001 A0 7618 ...
Page 90: ...Entry Exit Check of an MDS in an SLG Field 6 10 FC 56 J31069 D0155 U001 A0 7618 ...
Page 94: ...System Configuration 7 4 FC 56 J31069 D0155 U001 A0 7618 ...
Page 100: ...Commissioning Guidelines 8 6 FC 56 J31069 D0155 U001 A0 7618 ...
Page 101: ...9 1 FC 56 J31069 D0155 U001 A0 7618 Error Messages and Trouble Shooting 9 ...
Page 152: ...Programming MOBY ASM on PROFIBUS DP V1 B 30 FC 56 J31069 D0155 U001 A0 7618 ...