6AW5451-6XX01-1K
ES 030-K Manual
4 - 4
Subject to change without prior notice
RD: 08.2000
(4)J31069-D0136-U001-A0-7618
4.4
Connector X4
4.4.1
Bar Code Reading Wand
X4 9 pin D-Sub, female, slide lock
6
9
5
1
Pin Assignment
X4
9 pin D-Sub,
female
+ 5 V
1
2
Signal
Ground (0 V)
4
Buzzer
6
Data
7
9
V
scan
*
* only on ZA 14( connection for the reading gun)
Cable shield
4.4.2
MOBY-M
X3/X4 9 pin D-Sub, female, slide lock
6
9
5
1
Pin Assignment
X3/X4
9 pin D-Sub,
female
A1
5
6
Signal
Ground (0 V)
7
+ 24 V
8
A2
3
4
1
2
LBS
Connection
Cable shield
4.4.3
MOBY-I/L
X3/X4 9 pin D-Sub, female, screw lock
6
9
5
1
Pin Assignment
5
8
7
2
X3/X4
Signal
- Receive
+ 24 volt
Ground (0 V)
6
3
+ Send
- Send
+Receive
Cable shield
5
2
3
6
1
4
Pin No.
- Send
+ 24 volt
Ground (0 V)
+Receive
- Receive
+Send
Cable shield
Pin No.
Signal
SLG
ES 0 30-K
4.4.4
PROFIBUS-DP
X3/X4 Sub D, 9-socket, screwtype lock
6
9
5
1
Pin Assignment
1
3
4
5
Pin No.
Signal
PE
RxD/TxD-P
RTS
6
8
M5V2
P5V2
RxD/TxD-N
Designation
Protective ground
Data line B
Request to send
Data reference potential
Supply - plus
Data line A
I
max
= 100 mA
Note:
Connect cable shield to connector casing.