Setting of the Parameters in DB1 as SINEC L1 Master
Procedure selection
Supplied by
DR 41=3
User
Parameter
Address
Circulation list
DW 59 (DB,DW)
User
Bus user number
(master)
DL 41=0
User
(For the description of the data contents
see Chapter 3.2.1.1 to 3.2.1.5)
System Parameters
Supplied by
Receiving data
address
DW 42 (DB,DW)
User
Length of the
receiving buffer
DR 43 (byte)
User
Actual length
DR 44 (byte)
System
Error number for
the input
DL 43
System
Parameter
Address
Transmitter number
DL 57
System
(For the description of the data contents
see Chapter 3.2.1.1 to 3.2.1.5
Slave 1 Reception
Supplied by
Transmitting data
address
DW 45 (DB,DW)
User
Length of
transmitting buffer
DR 46 (byte)
User
Error number for
output
DL 46
System
Parameter
Address
Receiver number
DR 57
User
(For the description of the data contents
see Chapter 3.2.1.1 to 3.2.1.5
Slave 1 Transmit
Supplied by
Parameter
Address
DW 60 (DB,DW)
User
Receiving data
address
Length of the
receiving buffer
DR 61 (byte)
User
Actual length
DR 62 (byte)
System
Error number for
input
DL 61
System
DL 58
System
Transmitter number
(For the description of the data contents
see Chapter 3.2.1.1 to 3.2.1.5
Master Reception
Supplied by
Parameter
Address
Transmitting data
address
DW 63 (DB,DW)
User
Length of
transmitting buffer
DR 64 (byte)
User
Error number for
output
DL 64
System
Receiver number
DR 58
User
(For the description of the data contents
see Chapter 3.2.1.1 to 3.2.1.5
Master Transmit
The bus master requires a circulation list to determine the order
in which the slaves are scanned. A slave can be entered in the
list more than once. The respective slave numbers ( 1 to 31)
must be entered in one byte. Slave number 0 ends the
circulation list. Also, the SINEC L1 master always contains the
slave 1 (data exchange master <-> slave directly without
bus). Receiver number 31 sends a telegram to all slaves.
Actions/Reactions
The basic sequence of the data exchange has already been
explained in the section "Actions/Reactions Standard Serial
Interface".
The following deviations occur during SINEC L1 operation:
A telegram that has been sent to all bus users will not be
acknowledged by them.
Interrupt telegrams and laterial communication (SLAVE -->
SLAVE) are not possible.
Flag bytes 18 and 19 are to be used as flags (see Chapter
3.4.5.2 Expansion Serial Interface
The structure of the expansion serial interface is analogous to
the structure of the standard interface; with PREMID driver, but
without SINEC L1.
The flags to be used are FY 14 and 15 (see Chapter 3.3.2.10
Using the procedure LAUF,
“
XON/XOFF" can be switched on
from the transmitting side.
Additional Functions with LAUF:
Using the expansion serial interface, a start and a stop
character can be freely defined by setting DR 47 bit 5. The start
character is stored in DL 76; the stop character is stored in
DR 76. If FFH is used as start character, no start character will
be sent.
In addition, a checksum byte can be switched on with DR 47
bit 6. The checksum byte for reception is stored in DL 77; the
checksum byte for transmitting in DR 77. Before transmitting,
the checksum byte must be calculated by the user or checked
after the receipt of a telegram, respectively.