2.4
Program Configuration and Testing Aids
2.4.1
Digital Input/Output Simulation
6AW5451-8KA
for 8 DI/DQ on the ES 030-K X2, X3
2.4.2
Digital Input Simulation
6AW5451-7KA
for 16 DI on the ES 030-K X2, X3
A
E
Connection to
the peripheral
devices to be
simulated
to ES 030
E
Connection to
the peripheral
devices to be
simulated
to ES 030
E
The simulators can be connected directly to connectors X2 or X3. The 2 x 8 LEDs can be used to indicate the status of the digital
inputs and outputs or 16 digital inputs only when the 16 DIs are used.
The simulators are an important, as well as a helpful tool for programming and initial operation. They are simply connected into
the loop leading to the peripheral devices.