![Siemens Milltronics MCS Instruction Manual Download Page 22](http://html.mh-extra.com/html/siemens/milltronics-mcs/milltronics-mcs_instruction-manual_383277022.webp)
Page 18
MCS Belt Scale – INSTRUCTION MANUAL
7ML19985HN61
mmmmm
English
Test Load
The test load value is required for calibration of the integrator. Enter the calculated value
into the associated programming parameter of the integrator in kilograms per meter or
pounds per foot.
The test load value is calculated as follows:
Test load =
calibration weight (kg) or
(lb)
idler spacing
(m)
(ft)
Where: idler spacing = L/2 [minimum 0.6 m (2.0 ft)]
Final Calibration
Once installation and load cell balancing are complete, release the belt and allow it to
ride normally on the conveyor. Run the conveyor for at least fifteen minutes to limber the
belt prior to calibration.
Program the belt scale integrator with parameters suitable for the application. When
programming is complete, the system is ready for calibration.
Zero
Perform a zero calibration after the conveyor has been run long enough to allow the belt
to limber up and take its natural formation (10 to 20 minutes). Perform the zero calibration
as described in the integrator instruction manual while the conveyor is running empty.
A1
S1
R1
R2
A2
belt travel
L
Summary of Contents for Milltronics MCS
Page 1: ...Instruction Manual December 2003 MCS milltronics English Deutsch Español Français ...
Page 24: ...Page 20 MCS Belt Scale INSTRUCTION MANUAL 7ML19985HN61 mmmmm English ...
Page 44: ...Seite 40 Milltronics MCS Bandwaage BETRIEBSANLEITUNG 7ML19985HN61 mmmmm Deutsch ...
Page 64: ...Página 60 Báscula Milltronics MCS MANUAL DEL USUARIO 7ML19985HN61 mmmmm Español ...
Page 84: ...IQ300IX fm Page 5 Tuesday October 2 2001 1 43 PM ...