AT command interface
Version 8 dated 15.03.00
96
Siemens Information and Communication Products
Parameter
<length>
integer type value indicating in the text mode (+CMGF=1) the length of the message
body <data> (or <cdata>) in characters; or in PDU mode (+CMGF=0), the length of
the actual TP data unit in octets (i.e. the RP layer SMSC address octets are not counted
in the length)
<index>
integer type; value in the range of location numbers supported by the associated me-
mory
<mid>
GSM 03.41 CBM Message Identifier in integer format
<mr>
GSM 03.40 TP-Message-Reference in integer format
<oa>
GSM 03.40 TP-Originating-Address Address-Value field in string format; BCD num-
bers (or GSM default alphabet characters) are converted into characters; type of
address given by <tooa>
<pages>
GSM 03.41 CBM Page Parameter bits 0-3 in integer format
<pdu>
In the case of SMS: GSM 04.11 SC address followed by GSM 03.40 TPDU in hexade-
cimal format: ME/TA converts each octet of TP data unit into hexadecimal numbers
containing two IRA characters (e.g. octet with integer value 42 is presented to TE as
two characters 2A (IRA 50 and 65)). In the case of CBS: GSM 03.41 TPDU in hexade-
cimal format.
<page>
GSM 03.41 CBM Page Parameter bits 4-7 in integer format
<ra>
GSM 03.40 TP-Recipient-Address Address-Value field in string format; BCD num-
bers (or GSM default alphabet characters) are converted into characters; type of
address given by <tora>
<scts>
GSM 03.40 TP-Service-Centre-Time-Stamp in time-string format (refer <dt>)
<sn>
GSM 03.41 CBM Serial Number in integer format
<st>
GSM 03.40 TP-Status in integer format
<toda>
GSM 04.11 TP-Destination-Address Type-of-Address octet in integer format (when
first character of <da> is + (IRA 43) default is 145, otherwise default is 129)
<tooa>
GSM 04.11 TP-Originating-Address Type-of-Address octet in integer format (default
refer<toda>)
<tora>
GSM 04.11 TP-Recipient-Address Type-of-Address octet in integer format (default re-
fer<toda>)
Reference
GSM 07.05
Note