AT command interface
Version 8 dated 15.03.00
135
Siemens Information and Communication Products
AT^MONP
Monitor neighbour cells
Test command
AT^MONP[=<pe-
riod>]
Response
See execute command
Command is broken by any character sent to serial port
Parameter
<period>Display period in seconds
Execute command
AT^MONP
Response
chann rs dBm PLMN LAI NCC BCC C1 C2
46 49 -64 023102 0001 7 2 43 43
103 27 -83 023102 0001 7 3 21 21
39 22 -88 023102 0001 7 4 16 16
81 17 -93 023102 0001 7 5 11 11
104 16 -94 023102 0001 7 1 10 10
48 6 -104 023102 0001 7 7 0 0
54 3 -107 023102 0001 - - -1 -1
OK
Parameter:
chann
Channel number
rs
RSSI value (0–63)
dBm
Receiving level in dBm
PLMN
PLMN ID code
LAI
Location area ID
NCC
PLMN clour code
BCC
BS clour code
C1
C1 coefficient for base station selection
C2
C2 coefficient for base station selection
Reference
Note