    General information

14

Electrical connection

:

Warning

Risk of electric shock!

Components inside the appliance may have sharp 

edges. These may damage the connecting cable. Do 

not kink or pinch the connecting cable during 

installation.

The required connection data can be found on the 

rating plate inside the appliance; to do this, remove the 

metal mesh grease filter.

Length of the cable: approx. 1.30 m

This appliance complies with the EC interference 

suppression regulations.

:

Warning

Risk of electric shock!

It must always be possible to disconnect the appliance 

from the electricity supply. The appliance must only be 

connected to a protective contact socket which has 

been correctly installed. If the plug is no longer 

accessible following installation of the appliance, or a 

fixed connection is required, an all-pole isolating switch 

must be present on the installation side with a contact 

gap of at least 3 mm. The fixed connection must only 

be installed by an electrician.

Preparing the units

The fitted unit must be level and have sufficient load-

bearing capacity.

The max. weight of the extractor hood is 18 kg.

Appliance dimensions and safety clearances

Observe the appliance's dimensions.

Comply with the safety clearances.

If the installation instructions for the gas cooking 

appliances specify a different distance, the largest 

distance must always be provided for.

The fitted unit must be heat-resistant up to 90 °C.The 

fitted unit must still be sturdy after the cut-outs have 

been made.

To install the extractor hood in a wall-hanging 

cupboard, the extractor hood must be provided with the 

following dimensions:

1.

Make the cut-out for the exhaust air pipe. To do this, 

make an opening in the top or back panel of the 

fitted unit with an additional recess for the power 

cord.

2.

If the cabinet base is in place, remove it. Mark the 

fastening points on the inside of the cabinet and use 

a bradawl to make indentations where the holes are 

to be. To help you mark the fastening points, use the 

mounting piece provided.

Width

600 mm

Depth

Min. 320 mm

Depth

Min. 350 mm with lowering frame

Height

Min. 420 mm

Height

Min. 600 mm with CleanAir air recirculation 

module

 

 

PP

PP

PLQ

PP

Summary of Contents for LI64MA530B

Page 1: ......

Page 2: ...Register your product online siemens home com welcome HQ QVWUXFWLRQV IRU LQVWDOODWLRQ DQG XVH Extractor hood ...

Page 3: ... location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance may be us...

Page 4: ...coming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Grease deposits in the grease f...

Page 5: ...bles replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Causes of damage Caution Risk of damage due to corrosion Always switch on t...

Page 6: ...ontain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed through the outer wall a telescopic wall box should be used Air recirculation Note To bind odours in air recirculation mode you must install an activated carbon filter The different options for opera...

Page 7: ...n the metal grease filters or the activated charcoal filter are is saturated an audible signal sounds for approximately four seconds after the fan is switched off In addition the corresponding symbol appears on the display Metal grease filter Activated charcoal filter If you have not yet done so the metal grease filters should be cleaned or the activated charcoal filter changed For instructions on...

Page 8: ... the fan switches off automatically Automatic mode Switching on Touch the symbol The fan starts at setting ƒ Touch the symbol The optimum fan setting ƒ or is automatically set via a sensor Switching off Touch the or symbol to switch automatic mode off The fan switches off automatically if the sensor no longer detects a change in the air quality of the room Automatic mode can run for a maximum of 4...

Page 9: ...ed operation indicator Audible signal Switching on the audible signal When the fan is switched off press and hold the and symbols simultaneously for approximately three seconds An audible signal sounds as an acknowledgement Switching off the audible signal Repeat the Switching on the audible signal process 2Cleaning and maintenance Cleaningandmaintenance Warning Risk of burns The appliance will be...

Page 10: ... grease filters must not be wedged in Removing metal grease filter 1 Open the lock and fold down the metal grease filter While doing this place your other hand under the metal grease filter 2 Take the metal grease filter out of the holder Notes Grease may accumulate in the bottom of the metal grease filter Hold the metal grease filter level to prevent grease from dripping out 3 Clean the metal gre...

Page 11: ...n after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer You can therefore be sure that the repair is carried out by trained service technicians who ca...

Page 12: ...idual features are described which do not apply to your appliance This appliance is installed in a upper cabinet Follow the enclosed installation instructions for additional special accessories e g for circulating air mode The surfaces of the appliance are sensitive Avoid damaging them during installation Appliance width 60 cm Appliance width 90 cm PP PP ...

Page 13: ...ependent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system e g a chimney In combination with an activated vapour extractor hood room ai...

Page 14: ...stallation side with a contact gap of at least 3 mm The fixed connection must only be installed by an electrician Warning Danger of suffocation Packaging material is dangerous to children Never allow children to play with packaging material KGeneral information Generalinformation Exhaust air mode Warning Risk of death Risk of poisoning from flue gases that are drawn back in The exhaust air must no...

Page 15: ... the units The fitted unit must be level and have sufficient load bearing capacity The max weight of the extractor hood is 18 kg Appliance dimensions and safety clearances Observe the appliance s dimensions Comply with the safety clearances If the installation instructions for the gas cooking appliances specify a different distance the largest distance must always be provided for The fitted unit m...

Page 16: ...ke sure it is positioned correctly 2 Measure the distance between the appliance and the wall and mark this on the filler strip 3 If required shorten the filler strip to the required dimension Sliding out the appliance Note Before you remove the appliance protect the hob with a piece of polystyrene from the packaging 1 Use a flat blade screwdriver to push in the fastening bolt and turn it 90 until ...

Page 17: ...e 2 Lock the fastening bolts on the left and right 3 Fit the protective caps on the left and right ª 4 Establish the electrical connection Note The extractor hood s housing can be concealed within the upper cabinet In doing so you must observe the following The intermediate floor must not be placed on the extractor hood s housing The front panel must not be secured to the housing Access must be av...

Page 18: ... slot specified Connecting the pipes Note If an aluminium pipe is used smooth the area where it is to be connected before you connect it Exhaust air pipe dia 150 mm recommended size Fit the exhaust air pipe directly to the air pipe connector and seal the joint Exhaust air pipe dia 120 mm 1 Fit the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing c...

Page 19: ...en Installation 18 ...

Page 20: ......

Page 21: ...BSH Hausgeräte GmbH Carl Wery Straße 34 81739 München GERMANY 9001087137 9001087137 950918 siemens home com ...

Reviews: