background image

en

    Operating the appliance

6

1

Operating the appliance

Operating the appliance

These instructions apply to several appliance variants. 

It is possible that individual features are described 

which do not apply to your appliance.

Note: 

Switch on the extractor hood when you start 

cooking and switch it off again several minutes after you 

have finished cooking. This is the most effective way of 

removing the kitchen fumes.

Control panel model 1 and 2

Setting the fan

Switching on

Pull out the filter pull-out. The fan starts at the selected 

level.
Press buttons 1, 2 or 3 in order to change the fan 

strength.

Switching off

Slide the filter pull-out in as far as the limit stop.

Note: 

When you pull out the filter pull-out again, the fan 

starts up at the fan speed that was last selected.

Control panel model 3

Setting the fan

Switching on

Pull out the filter pull-out and press the 

#

 button. The 

fan starts at setting 2.
Press the + or - button to change the fan strength.

Switching off

Press the 

#

 button. Slide the filter pull-out in.

Intensive setting

You can use the intensive setting if there is a large 

build-up of odours and fumes/vapours.
Press the + button until all of the LEDs in the display 

light up. The intensive setting is activated. 
After approx. six minutes, the electronics automatically 

reduce the fan to a lower setting . If you want to end the 

intensive setting before the preset time expires, press 

the - button until the required fan setting is reached.
The run time is limited. The fan is then automatically 

reduced to a lower fan setting. You can switch back 

manually at any time.

Fan run-on time

If you slide in the filter pull-out, the run-on time will be 

activated for as long as the extractor hood is operating.
After approx. 10 minutes, the fan switches off 

automatically.

Lighting

The lighting can be switched on and off independently 

of the ventilation.
Press the 

A

 button.

Explanation

0, 

A

Light on/off

1

Fan speed 1

2

Fan speed 2

3

Fan speed 3

Explanation

<

Light on/off

#

Fan on/off

-

Reduces the fan speed

+

Increases the fan speeds/intensive setting

Summary of Contents for LI64MA530

Page 1: ...Register your product online siemens home bsh group com welcome HQ QVWUXFWLRQV IRU LQVWDOODWLRQ DQG XVH Extractor hood ...

Page 2: ...tallation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance ...

Page 3: ...coming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Grease deposits in the grease f...

Page 4: ...bles replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Causes of damage Caution Risk of damage due to corrosion Always switch on t...

Page 5: ...des OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed through ...

Page 6: ...button to change the fan strength Switching off Press the button Slide the filter pull out in Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Press the button until all of the LEDs in the display light up The intensive setting is activated After approx six minutes the electronics automatically reduce the fan to a lower setting If you wan...

Page 7: ...tal mesh grease filters also clean the holder for the metal mesh grease filters in the appliance using a damp cloth The metal mesh grease filters can be cleaned in the dishwasher or by hand By hand Note You can use a special grease solvent for stubborn dirt It can be ordered via the Online Shop Soak the metal mesh grease filters in a hot soapy solution Clean the filters with a brush and then rinse...

Page 8: ...es replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Malfunction table Replacing bulbs These instructions apply to several appliance variants It is possible that individual features are described which do not apply to your appliance Warning Risk o...

Page 9: ...Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer You can therefore be sure that the repair is carried out by t...

Page 10: ...ssible that individual features are described which do not apply to your appliance This appliance is installed in a upper cabinet Follow the enclosed installation instructions for additional special accessories e g for circulating air mode The surfaces of the appliance are sensitive Avoid damaging them during installation Appliance width 60 cm Appliance width 90 cm 2x 2x ...

Page 11: ...pendent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system e g a chimney In combination with an activated vapour extractor hood room air...

Page 12: ...al installation must only be wired by a professional electrician We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit Warning Danger of suffocation Packaging material is dangerous to children Never allow children to play with packaging material KGeneral information GeneralinformationExhaust air mode Warning Risk of death Risk of poisoning from flu...

Page 13: ...end installing a residual current circuit breaker RCCB in the appliance s power supply circuit Preparing the units The fitted unit must be level and have sufficient load bearing capacity The max weight of the extractor hood is 18 kg Appliance dimensions and safety clearances Observe the appliance s dimensions Comply with the safety clearances If the installation instructions for the gas cooking ap...

Page 14: ...re the handle strip to the filter pull out 2 Connect the power cord provided to the appliance 3 Use the strain relief to secure the power cord in place 4 Screw the two angle brackets to the appliance Ensure that the screws are positioned correctly ª Screw in the screws until 8 mm of the threaded section is still protruding 5Installation InstallationInstallation 1 Use the angle brackets to hang the...

Page 15: ...ales service Appliance width 90 cm You must also screw the appliance onto the side upper cabinets Change the filter pull out s limit stop On some versions of the appliance the limit stop for the filter pull out can be changed Spacers are included with these appliances in order to set the appliance s handle strip so that it is flush with the fitted unit 1 Pull the filter pull out forwards 2 Shorten...

Page 16: ...BSH Hausgeräte GmbH Carl Wery Straße 34 81739 München GERMANY 9001057428 9001057428 960915 siemens home bsh group com 0DQXIDFWXUHG E 6 DXVJHUlWH PE XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV ...