General information    

en

13

K

General information

General information

Exhaust air mode

:

Warning – Risk of death! 

Risk of poisoning from flue gases that are drawn back 

in. The exhaust air must not be conveyed into a 

functioning smoke or exhaust gas flue or into a shaft 

which is used to ventilate installation rooms that contain 

heating appliances. If the exhaust air is to be conveyed 

into a non-functioning smoke or exhaust gas flue, you 

must obtain the consent of the heating engineer 

responsible.

If the exhaust air is conveyed through the outer wall, a 

telescopic wall box should be used.

Exhaust duct

Note: 

The device manufacturer does not assume any 

warranty for complaints attributable to the pipe section.

The device achieves its optimum performance by 

means of a short, straight exhaust air pipe and as 

large a pipe diameter as possible.

As a result of long rough exhaust air pipes, many 

pipe bends or pipe diameters that are smaller than 

150 mm, the optimum extraction performance is not 

achieved and fan noise is increased.

The pipes or hoses for laying the exhaust air line 

must consist of non-combustible material.

Round pipes

 

An inner diameter of 150 mm, but at least 120 mm, is 

recommended.

Flat ducts

 

The inner cross-section must correspond to the 

diameter of the round pipes.

dia. 150 mm ca. 177 cm

2

dia. 120 mm ca. 113 cm

2

Flat ducts should not have any sharp deflections.

Use sealing strips for deviating pipe diameters.

Preparing the ceiling

The ceiling must be flat, horizontal and have 

adequate load-bearing capacity.

The depth of the bore holes must be the same 

length as the screws. The wall plugs must have a 

secure grip.

The enclosed screws and wall plugs are suitable for 

solid brickwork. Suitable fasteners must be used for 

other structures (e.g. plasterboard, porous concrete, 

poroton bricks).

The max. weight of the extractor hood is 

50 kg

.

Electrical connection

:

Warning – Risk of electric shock! 

Components inside the appliance may have sharp 

edges. These may damage the connecting cable. Do 

not kink or pinch the connecting cable during 

installation.

The required connection data can be found on the 

rating plate inside the appliance; to do this, remove the 

metal mesh grease filter.

Length of the cable: approx. 1.30 m

This appliance complies with the EC interference 

suppression regulations.

:

Warning – Risk of electric shock! 

It must always be possible to disconnect the appliance 

from the electricity supply. The appliance must only be 

connected to a protective contact socket that has been 

correctly installed. 

The mains plug of the mains power cable must be 

easily accessible after installation of the appliance. If 

this is not possible, an all-pole isolating switch must be 

integrated into the permanent electrical installation 

according to the conditions of overvoltage category III 

and according to the installation regulations.

The permanent electrical installation must only be wired 

by a professional electrician. We recommend installing 

a residual-current circuit breaker (RCCB) in the 

appliance's power supply circuit.

Summary of Contents for LF97BBM50

Page 1: ...OM EUROPE Thanks for choosing ImportAppliances for your kitchen appliance purchase We hope you are enjoying the convenience quality and affordability of your new appliance If you have any issues or questions please contact us via email info ImportAppliances com User Manual ...

Page 2: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE 5HJLVWHU RXU SURGXFW RQOLQH VLHPHQV KRPH EVK JURXS FRP ZHOFRPH en Instructions for installation and use Extractor hood ...

Page 3: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE ...

Page 4: ...he appliance works perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000...

Page 5: ... cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode War...

Page 6: ...after sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a damp cloth only Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Causes of damage Caution Risk of damage due to corros...

Page 7: ...disposal Dispose of packaging in an environmentally friendly manner ÇOperating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the co...

Page 8: ...he circuit breaker in the fuse box Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Warning Risk of injury Components inside the appliance may have sharp edges Wear protective gloves Caution There is a risk of surface damage if you do not peel off the protective film Remove the protective film from all parts of the appliance befor...

Page 9: ...water Clean the filters with a brush and then rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled me...

Page 10: ...tomer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer You can therefore be sure that the repair is carried out by trained service technicians who carry original spare parts for your appliances Accessories not included in the scope of delivery Note These instructions apply to several appliance models It may be the case that an optional acces...

Page 11: ...g to the safety instructions The installer is responsible for ensuring that the appliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of ...

Page 12: ...air must therefore always be ensured An incoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors w...

Page 13: ...e an all pole isolating switch must be integrated into the permanent electrical installation according to the conditions of overvoltage category III and according to the installation regulations The permanent electrical installation must only be wired by a professional electrician We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit Warning Risk o...

Page 14: ...ons Use sealing strips for deviating pipe diameters Preparing the ceiling The ceiling must be flat horizontal and have adequate load bearing capacity The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboard porous ...

Page 15: ...les to a depth of 80 mm for the fasteners and press in the wall plugs flush with the ceiling 5 Fasten the upper part of the support frame to the ceiling with 4 screws Note Ensure that the support frame is in the correct position The middle bracket defines the preferred side and must be facing the hob control elements Fitting the lower support frame Fasten the upper and lower part of the support fr...

Page 16: ...pipe directly to the air pipe connector and seal Exhaust air pipe Ø 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appropriately Attaching the flue duct Warning Risk of injury Components inside the appliance may have sharp edges Wear protective gloves 1 Separate the flue ducts To do this remove th...

Page 17: ...m THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE 0DQXIDFWXUHG E 6 DXVJHUlWH PE XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV 6 DXVJHUlWH PE DUO HU 6WU 0 QFKHQ VLHPHQV KRPH EVK JURXS FRP 50 1 9001359408 9001359408 980615 ...

Reviews: