background image

LC 75 . .
LC 90 . .

LC 86950 GB

Operating and
installation instructions

Summary of Contents for LC 86950 GB

Page 1: ...LC 75 LC 90 LC 86950 GB Operating and installation instructions ...

Page 2: ...2 mind 650 mind 550 Abb 1 ELECTRO Fig 1 GAZ ...

Page 3: ...cking etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the combined ventilation system for the entire household must be taken into consideration This rule does not apply to the ...

Page 4: ...taneously Before using your appliance for the first time please read these Instructions for Use carefully They contain important information concerning your personal safety as well as on use and care of the appliance Please retain the operating and installation instructions for a subsequent owner Do not use the appliance if damaged The appliance is not intended for use by young children or infirme...

Page 5: ...tching off Repeat the process with the light switched on After approx 3 seconds the light switches off to acknowledge the setting Operating procedure Light Fan OFF Reduce fan speed Fan ON and increase speed Display for fan setting Fan follow on Acoustic signal When a button is pressed this is verified by an acoustic signal Switching off the acoustic signal Simultaneously press buttons 0 and until ...

Page 6: ...is sounded for 10 seconds after the fan has switched off and an appears in the display The grease filters should be cleaned straight away Cleaning the metal grease filters The filters can be cleaned in a dish washer It is however possible that they will become slightly discoloured Important Metal filters that are saturated with grease should not be washed together with other dishes etc When cleani...

Page 7: ... can be obtained from any authorized dealer see optional accessories Use original filters only By doing so you will obtain maximum performance from your extractor hood Disposing of the old activated carbon filter There are no pollutants in the activated carbon filters They can therefore be disposed of as part of your normal domestic refuse Activated carbon filter For neutralizing odours in recircu...

Page 8: ...es Use a mild non abrasive stainless steel cleaner Clean the surface in the same direction as it has been ground and polished Do not use any of the following to clean stainless steel surfaces abrasive sponges cleaning agents containing sand soda acid or chloride Aluminium painted and plastic surfaces Use a soft non linting window cloth or micro fibre cloth Do not use dry cloths Use a mild window c...

Page 9: ...s or if a fault occurs please call Customer Service See list of Customer Service representatives When you call please quote the following Setting the saturation indicator If it becomes necessary to change the operating mode exhaust air recirculating mode the saturation indicator for the filters must also be altered see Installation Instructions E Nr FD Enter the relevant numbers into the box above...

Page 10: ...pliance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment by disposing of packaging materials in an environmentally friendly manner Please ask your dealer or inquire at your local authority about current means of disposal The extractor hood can be used in e...

Page 11: ...r for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air can flow through non lockable openings e g in doors windows and via the air intake exhaust air wall box or by other technical measures such as reciprocal interlocking etc If the air intake is inadequate there is ...

Page 12: ...ld be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters Insert sealing strip For exhaust air mode ensure that there is an adequate supply of fresh air Circulating air mode With activated carbon filter if exhaust air mode is not possible mind 130 740 1170 535 280 245 620 500 900 75 300 mind 500 The complete installation set can be obtained from special...

Page 13: ...ectly into the mains The extractor hood should only be connected to the electricity supply by a properly qualified electrician A separator must be installed in the household circuit A suitable separator is a switch that has a contact gap of more than 3 mm and interrupts all poles Such devices include circuit breakers and contactors This extractor hood corresponds to EC regulations concerning RF in...

Page 14: ...hat the minimum distance between the hob and the extractor hood is maintained 550 mm for an electric hob and 650 mm for a gas hob The bottom edge of the template corresponds to the lower edge of the extractor hood glass screen 4 Drill 3 x l 8 mm holes for the extractor hood and 2 x l 8 mm holes for the chimney panelling Insert plugs into the holes so that they are flush with the wall Note Take int...

Page 15: ...tlet pipe 10 Connect the hood to the electricity supply 11 Remove the protective film from the two flue ducts Avoid damage to the sensitive surface 1 2 1 2 3 Protect the cover panels from scratches for example by laying the template used for marking the wall over the top edge of the lower section 13 Insert the complete flue duct at an angle into the glass shield and swivel backwards 14 Carefully p...

Page 16: ...360732 LZ 51850 1 2 3 5 6 7 2x 10x 2x 4 2x 9000 018 898 Printed in Germany 0704 Es Siemens Electrogeräte GmbH ...

Reviews: