Page 1: ...IP Module IP Module CFVA IP IP Module CVVA IP User manual Issue 07 2005 Fire Safety Security Products Siemens Building Technologies ...

Page 2: ...nt nicht ohne unsere vorgängige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder außerhalb des Zweckes verwenden zu dem es ihm übergeben worden ist We reserve all rights in this document and in the subject thereof By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part no...

Page 3: ...ge using Microsoft Internet Explorer 17 9 1 2 Calling up the device homepage using the Web Cam IP Manager 17 9 2 Components of the device homepage 19 10 Configuring network settings 20 10 1 Changing the device IP address 21 9 1 1 Changing the device IP address via the device homepage 21 9 1 2 Changing the IP address using the Web Cam IP Manager 22 11 Configuring image parameters 24 11 1 Configurin...

Page 4: ......

Page 5: ...r PC via an internet connection The live video images are transmitted via a TCP IP based network and displayed using an http browser e g Netscape 7 0 Mozilla or Internet Explorer The image parameters and network settings of the dome camera can be configured via the network About this manual This user manual explains how to install and configure the IP Module Please read the manual carefully to fam...

Page 6: ...ect the camera and the IP Module from the power supply and have it checked by your authorized dealer before using it again Danger of electric shock This equipment has been tested and found to comply with the limits for a Class B digital device These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment may generate uses and c...

Page 7: ...ower supply 0 12 kg CAPA2410 P230 2GF1800 8BJ 24 V AC camera power supply 0 30 kg 3 2 Ordering data for IP Module CVVA IP Type Item no Description Weight CVVA IP 2GF1185 8AG IP Module for 12 V DC 24 V DC vandal proof fix dome camera 0 62 kg Extra accessories not included in the standard supply PSU230 12 2GF1800 8BE 12 V DC camera power supply 0 12 kg CAPA2410 P230 2GF1800 8BJ 24 V AC camera power ...

Page 8: ...can be made available to the relevant authorities by Siemens Building Technologies Fire Security Products GmbH Co oHG Siemensallee 84 D 76187 Karlsruhe Application in accordance with the Electromagnetic Compatibility Directive The device has been designed for industrial use and satisfies the following requirements Electromagnetic emissions EN 61000 6 3 Electromagnetic immunity EN 50130 4 A2 8 Siem...

Page 9: ...0 Protocols ARP BOOTP DHCP TCP IP HTTP ICMP SNMP FTP and DNS Installation IP address configurable via ARP BOOTP DHCP connection to twisted pair RJ45 Ethernet Network connection 10BaseT Ethernet or 100BaseTX Fast Ethernet auto sensing full half duplex Image formats QCIF 176x144 CIF 352x288 4CIF 704x576 interlaced Image transmission Motion JPEG multipart x mixed replace content type user configurabl...

Page 10: ...version 7 0 Protocols ARP BOOTP DHCP TCP IP HTTP ICMP SNMP FTP and DNS Installation IP address configurable via ARP BOOTP DHCP connection to twisted pair RJ45 Ethernet Network connection 10BaseT Ethernet or 100BaseTX Fast Ethernet auto sensing full half duplex Image formats QCIF 176x144 CIF 352x288 4CIF 704x576 interlaced Image transmission Motion JPEG multipart x mixed replace content type user c...

Page 11: ... plugs 2 Mount the IP Module to the ceiling wall 3 Connect the BNC cable 12 to the connector socket 4 in the IP Module Installation and connection of the dome camera 4 Connect the video output from the dome camera to the BNC cable video input 11 5 Connect the electrical supply for the dome camera to connector socket 5 6 Remove the dome from the camera body illustration D 11 Siemens Building Techno...

Page 12: ...cation with the device for the first time See section 7 Establishing initial communication with the device 11 A test monitor can be connected to the BNC socket 6 when configuring the camera 12 Configure the dome camera as required Refer to the dome camera manual for set up instructions 13 Place the dome back on the camera and screw it in position Clean the dome after installation using a soft lint...

Page 13: ...ect the electrical supply to the connector socket 4 9 If an analog video output is required connect the outgoing BNC cable to the BNC connection line 5 Installation and connection of the dome camera 10 Open the dome housing illustration D 11 Gently pull the dome cables electrical supply cable and BNC cables out of the dome camera 12 Connect the Y cable lead 12 to the dome camera video output 13 Co...

Page 14: ... context menu 3 Select Internet protocol TCP IP in the Properties dialogue window and click the Properties button 4 Activate the check box for Use the following IP address in the TCP IP properties dialogue window 5 Enter 192 168 100 101 for the IP address and 255 255 255 0 for the subnet mask 6 Click on OK 7 Restart your client PC The client PC is now located in the same network segment as the dev...

Page 15: ...Enter key The ensuing network route ensures device accessibility Note that you should enter your own client PC IP address instead of 10 11 12 13 4 Check that there is communication with the device by typing ping 192 168 100 100 5 You must now allocate the desired IP address to the device via the device s homepage See section 10 1 Changing the device IP address 15 Siemens Building Technologies Fire...

Page 16: ...ng a new IP address to your device See section 10 1 Changing the device IP address 1 Type the following command in the your client PC s command prompt screen 2 ping xxx xxx xxx xxx xxx xxx xxx xxx 192 168 100 100 if the IP address set by the factory is used xxx xxx xxx xxx the IP address you have allocated to the device e g 141 73 31 3 3 Press the Enter key 16 Siemens Building Technologies Fire Sa...

Page 17: ... homepage will be displayed 9 1 2 Calling up the device homepage using the Web Cam IP Manager This assumes that The Web Cam IP Manager and all the devices are located in the same network segment If a device and the Web Cam IP Manager are not located in the same network segment you must ensure that associated gateway router passes the SSDP multicast messages sent by the Web Cam IP Manager to the ne...

Page 18: ...ith their IP addresses and MAC addresses Each device s IP address or MAC address is unique 3 Select the device whose homepage you want to call up 4 Click on the Home page of selected device button The homepage of the selected device is now called up See section 9 2 Components of the device homepage 18 Siemens Building Technologies Fire Safety Security Products ...

Page 19: ...for displaying live video images See section 15 1 Displaying live video 2 Submenu 3 Language selection list box Standard setting English 4 Main menus 5 Display area for live video images See section 15 1 Displaying live video 19 Siemens Building Technologies Fire Safety Security Products ...

Page 20: ...ostname entered here appears in the Web Cam IP Manager as the name of the device See section 9 1 2 Calling up the device homepage using the Web Cam IP Manager Automatic network configuration DHCP If you activate automatic network configuration a DHCP or BOOTP server will automatically allocate an IP address a subnet mask and a gateway to your device See section 9 1 1 Changing the device IP address...

Page 21: ... Configuration menu The Network settings dialogue window opens 3 Activate the Automatic network configuration DHCP check box Each time the device is restarted the DHCP or BOOTP server will automatically reinstate the network settings IP address subnet mask and gateway if applicable 4 Restart your IP Module See section 14 Restarting the IP Module Manual IP address and subnet mask allocation 1 Call ...

Page 22: ...28 the device can be accessed by a client PC with IP address 141 73 31 162 and subnet mask 255 255 255 128 The client PC IP address and that of the device are both located in the same network segment 9 1 2 Changing the IP address using the Web Cam IP Manager You may only change the device IP address in the first 20 minutes after initial start up This assumes that The Web Cam IP Manager and all the...

Page 23: ...anually enter the desired IP address subnet mask and gateway if required or activate the check box if you want the DHCP server to determine these parameters The settings will be adopted immediately This process takes about 40 seconds Next the device homepage will be displayed allowing you to check the entries in Network settings in the Configuration menu 23 Siemens Building Technologies Fire Safet...

Page 24: ...Live video image saturation 0 to 100 Flip picture Activate the check box to rotate the image through 180 degrees the image now appears upside down 4 Click on Save 11 2 Configuring text overlay 1 Call up the device homepage See section 9 1 Calling up the device homepage 2 Select Image parameters in the Configuration menu The Image parameters dialogue window opens 3 Enter the desired settings in thi...

Page 25: ...ng JPEG encoder settings The live video image can be displayed at the following resolutions Low Standard High You can allocate a quality level to each resolution The table below shows guideline values in kilobytes for the size of data stream required for image transmission The size of the data stream depends on the resolution setting and the chosen quality level Image size Low quality Medium quali...

Page 26: ...et the quality level to Medium 6 Select the font size for the text overlay from the options in the Diplay Font Size list box The following options are available no text overlay Small Large 7 Select the input signal from the options in the Video Standard list box The following options are available PAL CCIR NTSC EIA 8 Click on Save 26 Siemens Building Technologies Fire Safety Security Products ...

Page 27: ...on menu The Date and Time dialogue window opens Fig 5 Date and time The time and date that were current when the device start page was loaded appear in the relevant boxes You can set the device s built in real time clock here 3 Choose the desired settings from the list of options for each field 4 Click on Save 27 Siemens Building Technologies Fire Safety Security Products ...

Page 28: ...tion User name config For image access User name image 1 Call up the device homepage See section 9 1 Calling up the device homepage 2 Select Security in the Configuration menu The Security dialogue window opens Fig 6 Security 3 Enter the desired user name max 32 characters 4 Enter the desired password max 32 characters 5 Confirm the password 6 Click on Save 28 Siemens Building Technologies Fire Sa...

Page 29: ...nual restart Time controlled restart Restart by Ping Watchdog Manual restart 1 Click on the Restart now button The device will restart immediately The device requires about 40 seconds for the restart No communication can take place with the device during this period Time controlled restart 1 Activate the Enable time controlled restart check box 2 Enter the time in the box HH MM e g 12 00 3 Click o...

Page 30: ...ng the Remote Host to Ping you have entered every 30 seconds 4 Enter the desired cycle time in seconds in the Timeout box e g 125 A restart will be triggered if the return ping from the Remote Host for Ping you have entered is not received within 125 seconds The time out value must be a multiple of the cycle time the value entered in Frequency In the event of an unexpected system problem this ensu...

Page 31: ...sed to display the live images This assumes that You have installed a Gecko based browser Mozilla Netscape 7 This browser can be downloaded from http mozilla org http netscape com download Or You have installed Microsoft Internet Explorer 5 5 or later This browser can be downloaded from http microsoft com windows ie In addition to Microsoft Internet Explorer 5 5 or later you will need to install J...

Page 32: ...uality The following options are available Low QCIF 176 x 144 pixels Standard CIF 352 x 288 pixels High 4CIF 704 x 567 pixels The default resolution is Standard The image quality is set in Image Parameters in the Configuration menu See section 11 1 Configuring general image parameters 15 3 Storing still pictures You can store still pictures in JPG and BMP format 1 Click on the Pause button 2 Choos...

Page 33: ...ernet through an ISP Your router will be allocated dynamic IP addresses for internet access by your ISP i e when dialing in via an ISP the client the computer attempting to make the connection will automatically be assigned a temporary free IP address when logging on This means that the client acts as an internet server for the time it is on line The term dynamic means that the connection to the I...

Page 34: ...et 1 Allocate a fixed IP address to your device e g 192 168 100 100 See section 10 1 Changing the device IP address 2 Set the time and duration of the dynamic IP address change cycle used by the ISP via the router 3 Register your domain name with a Domain Name Server DNS e g www DynDns org so that the IP address can be assigned to the domain name Each time the connection to the ISP is reestablishe...

Page 35: ... 352 x 288 size 2 4CIF input 704 x 576 szX Image width in pixels szY Image width in pixels ofX Image offset measured horizontally from the left hand side of the digital image ofY Image offset measured vertically from the top edge of the digital image qual JPEG coding quality in the range 0 100 bw Black white display properties 1 black white 0 color limit Band width limit in kilobits per second Tab...

Page 36: ...ink between the desired IP address and the device s MAC address must occur within 60 seconds arp s IP address MAC address e g arp s 192 168 1 100 00 d0 4a 00 10 01 The IP address you use must be located in the same network segment as the client PC that you have used to create the link If in doubt refer to the following example The client PC s IP address is 192 168 1 1 and the subnet mask is 255 25...

Page 37: ...of client PC 14 changing the device IP address 21 IP Module Restarting the IP Module 29 IP Module Installing CFVA IP 11 Installing CVVA IP 12 J JPEG encoder settings Configuring JPEG encoder settings 25 L Live video Displaying live video 31 Live video images Embedding live video images in a dedicated HTML page 35 N Network route Mapping a network route 14 P Password Configuring passwords 28 R Reso...