IONPURE
®
VNX50HH-2 CEDI Modules
Page 10
IP-MAN-VNX50HH2
Figure 2-3:
Grounding Rod
2.3. Inspect the Module
•
Do not uncrate the module prior to moving it into its final location. After uncrating it, inspect it
for any signs of damage. If damage is apparent, immediately notify your Local Service
Provider and the carrier.
2.4. Operating Requirements
In order to operate to specification, the VNX module must have the following conditions present.
If any of these conditions are unmet, do not attempt to install the VNX module without specific
instructions from your Local Service Provider’s Technical Support.
•
Operating Environment
The VNX module requires indoor installation out of direct sunlight.
The maximum ambient room temperature should not exceed 113
°
F (45° C).
The module can tolerate humidity of up to 90%, as long as
condensation does not occur.
•
Space Requirements
The physical dimensions of the VNX Module are given in appendix A. In addition to the
size of the module itself, the arrangement of the piping and electrical connections
determine the amount of space the module needs to operate. This arrangement varies
from site to site, depending on the conditions at a particular location.
•
Electrical Requirements
The VNX module requires the following power sources. In all cases the cathodes must be
at ground potential.
Table 2-2:
Electrical requirements for the VNX Modules
Model
Nominal Flow Rate
DC Power
VNX50HH-2
40 gpm (9.1 m
3
/hr)
0-600 VDC, 8 Amps