wclient.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
10-101
Nur für den internen Gebrauch
Workpoint Clients
optiPoint 500
●
Ring, alarm and key tones are transferred to the internal loudspeaker and not to an exter-
nal loudspeaker connected to the optiPoint acoustic adapter.
●
The volume keys on the optiPoint terminal are used to adjust the volume level of the inter-
nal loudspeaker and any connected external loudspeaker. The volume of the external
loudspeaker can also be adjusted using the external amplifier.
Figure 10-50
Y Cable for optiPoint acoustic adapter
Assignment of the MW4 connection sockets:
Internal resistance: 0
Ω
; 10 µF
Level (for PCM -20 dBm): -4.8 dBm (at volume level 8; 0.775
V = 0 dBm)
Sense lead to GND: int. loudspeaker deactivated; only active
for tone ringing.
Input level -50 dBm: -12 dBm PCM signal
Input resistance: 150 k
Ω
parallel to 220 nF in series with 36
k
Ω
Sense lead to GND: internal microphone deactivated.
Pin
Signal
1
sense lead
2
NF+
3
Free
4
GND
Pin
Signal
1
+5V
2
GND
3
Free
4
sense lead
microphone
4
1
Y cable
acoustic adapter
Loudspeaker