Expanding and Upgrading HiPath 3000
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
9-24
HiPath 3000/5000 V9, Service documentation
exup.fm
HiPath 3000Expanding
9.1.3.8
19-Inch Cabinet Installation for PB3000
Proceed as follows to install the PB3000 in a 19-inch cabinet:
7
Caution
The battery compartment including batteries and/or LUNA2 power supply must be
removed before installation!
Step
Activity
1.
Attach the angle brackets (A), to attach the PB3000 with two screws on both sides
(left and right) of the frame of the 19-inch cabinet.
Note: Necessary height units for 19-inch cabinet assembly: 4 HE
(one height unit (HE) corresponds to approx. 1.7’’=43 mm)
2.
Attach both angle brackets (B) to the PB3000 with 2 screws on both sides (left and
right).
3.
Insert the PB3000 between the angel brackets in the 19-inch cabinet (to the limit
stop).
4.
Secure the two angle brackets of the PB3000 each with 2 screws on the frame of
the 19-cabinet.
5.
Reinstall the battery compartment and/or the LUNA2 power supply and reattach
the front panel of the PB3000 (see Section 9.1.3.6.1 and Section 9.1.3.6.2).
The PB3000 can now be used.
B
A
C