Starting Up HiPath 3000
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
5-18
HiPath 3000/5000 V9, Service documentation
start_h3.fm
Starting Up HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300
5.2.6
Customer-Specific Programming
You can program the system using one of the following tools:
●
Assistant T (programming telephone, refer to Appendix A)
●
HiPath 3000/5000 Manager E (PC tool)
Refer to the HiPath 3000/5000 Manager E Help for information on programming individual fea-
tures.
5.2.7
Performing a System Check
Checking the telephones
●
The display must be checked on every telephone. The phone number, date and time are
normally displayed.
●
If a different text appears (“Gateway not found”, for example), this means that there is an
error.
Correct the error by following the administration instructions for the relevant telephone.
●
Perform random terminal tests as described in Section 12.4.11 on all telephones.
Checking for proper system booting
●
Set up internal and external calls at random to check if the system is functioning properly.
>
Changes to the system (for example key programming) made using HiPath 3000/
5000 Manager E during an offline programming session will be lost when the data-
base is loaded.
When you program the system offline, the assignments of trunk and subscriber ports
depend on the order in which the boards are inserted. Usually, the boards are insert-
ed from the lowest slot to the highest.