boards.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
3-301
Nur für den internen Gebrauch
Boards for HiPath 3000
Peripheral boards
Installing the ECGM tool and configuring the CAS protocol converter
This section describes how to install the ECGM tool on the service PC and configure the CAS
protocol converter on the TMCAS board.
The ECGM tool supports the following actions:
●
Extender, database and software download
●
CAS protocol configuration
●
Database programming
●
Trace options
Procedure
Step
Activity
1.
Create directory
c:\ecginst
on the service PC
.
2.
Set up the connection to the download server (for information on this, contact your
local ITSC) and copy the following files into the directory
c:\ecginst
:
●
e1v0xx.exe
(for example,
e140ah.exe
)
●
Ee1v0yy.exe
(for example,
Ee140am.exe
)
●
Ecgm_vzz.exe
(for example
Ecgm_4aa.exe
)
Explanation of the variables:
●
v =
software version
●
xx =
country version of a file
●
yy =
file version for channels
●
zz =
file version for maintenance
3.
Run .exe files. This will extract the following files, for example:
●
Ecgm.cab
(WinZip file)
●
Setup.lst
(LST file)
●
Setup.exe
(EXE file)
●
4brazil.iam
(IAM file)
●
Ecg_edb4.ein
(EIN file)
●
4brazil.eam
(EAM file)
●
E140ah.sin
(SIN file)
●
E140ah.pnm
(PNM file)
●
X140pai.pnm
(PNM file)
●
X130aq.pnm
(PNM file)
4.
Execute
Setup.exe
file. This will create the directory
ecgm
and extract various
files.
5.
Copy
vbrazil.iyy
(for example,
4brazil.iam
) to the directory
ecgm
.
6.
Run the file
ecgm.exe
.
Summary of Contents for HiPath 3000 Series