Boards for HiPath 3000
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
3-252
HiPath 3000/5000 V9, Service documentation
boards.fm
Peripheral boards
Administration of the CAS protocol converter
A separate tool, the CAS Manager, is used to download the software and administer the TCAS-
2 and TCASR-2. The CAS Manager software is stored on a CD supplied with the card. For in-
formation on how to install the CAS Manager software on the Service PC, refer to the readme
file.
The following options are available for accessing the cards:
●
Via the V.24 interface (9-pin MINI DIN jack X803) and the connection cable C39195-
A9700-B532.
●
Via the Ethernet (10/100BaseT) interface (RJ45 jack X804).
●
Via the optional analog modem (modem kit F31505-E1-A147). In this case, you will need
to establish a connection from the analog modem (RJ45 jack X805) to a free port in an an-
alog subscriber line module via the RJ45 cable C39195-Z7208-A10 supplied with the mo-
dem kit (see Figure 3-85).
Figure 3-84
TCAS-2, TCASR-2 (for selected countries only) – Connection Options for Card
Administration using CAS Manager
Analog sub-
scriber line
module
Analog trunk
board
TCAS-2 /
TCASR-2
Modem
(optional)
HiPath 3550 / HiPath 3500
X803
V.24 interface
PSTN
X804
Ethernet (10/100BaseT) interface
X805
Establish connec-
tion.
CAS
Manager
IP Network
CAS
Manager
CAS
Manager
Summary of Contents for HiPath 3000 Series
Page 1252: ......