boards.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
3-145
Nur für den internen Gebrauch
Boards for HiPath 3000
Peripheral boards
14
32
27
23
19
14
10
15
29
25
20
16
12
7
16
27
22
18
13
9
5
Table 3-63
HiPath 3550 - Maximum Number of Corded Telephones Depending on the
Number of BS3/3 Base Stations Connected to SLC16N and BS4s con-
nected to SLC16N (not for U.S.)
Number
of BS3/3s and BS4s
connected via 2xU
P0/E
to SLC16N
Maximum number of corded telephones
Analog telephones
0
1-10
11-20
21-30
31-40
41-50
optiPoint 500 (digital telephones)
1
64
60
56
51
47
42
2
60
56
52
47
43
39
3
57
52
48
43
39
35
4
53
48
44
40
35
31
5
49
44
40
36
31
27
6
45
40
36
32
27
23
7
41
37
32
28
23
19
8
37
33
28
24
20
15
Table 3-62
HiPath 3550 - Maximum Number of Corded Telephones Depending on the
Number of BS3/1 Base Stations Connected to SLC16N and BS4s con-
nected to SLC16N (not for U.S.)
Number
of BS3/1s and BS4s
connected via 1xU
P0/E
to
SLC16N
Maximum number of corded telephones
Analog telephones
0
1-10
11-20
21-30
31-40
41-50
optiPoint 500 (digital telephones)
Summary of Contents for HiPath 3000 Series