power_calc.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
D-11
Nur für den internen Gebrauch
Identifying System Power Requirements
Workpoint Client, Add-On Device, and Adapter Power Requirements
D.6
Workpoint Client, Add-On Device, and Adapter Power
Requirements
An average power requirement is specified, which is identified at a traffic flow of 0.15 Erlang.
Table D-11
Workpoint Client, Add-On Device, and Adapter Power Requirements
Workpoint Client
Net Power Requirement in W
(from -48 V input)
OpenStage
(CorNet-IP
connection
variant)
OpenStage 20
0.0
1
OpenStage 40
OpenStage 60
OpenStage 80
OpenStage
(TDM connec-
tion variant)
OpenStage 10
0.85 W
OpenStage 20
OpenStage 40
1.1 W
OpenStage 60
OpenStage 80
OpenStage Key Module
0.0
OpenStage BLF
0.0
2
OpenStage PhoneAdapter
optiPoint 410
optiPoint 420
optiPoint 410 entry, optiPoint 410 entry S
optiPoint 410 economy, optiPoint 410
economy S
optiPoint 410 standard, optiPoint 410 stan-
dard S
optiPoint 410 advance, optiPoint 410 ad-
vance S
optiPoint 420 economy, optiPoint 420
economy S
optiPoint 420 economy plus, optiPoint 420
economy plus S
optiPoint 420 standard, optiPoint 420 stan-
dard S
optiPoint 420 advance, optiPoint 420 ad-
vance S
optiPoint self labeling key module
optiPoint 410 display module
Summary of Contents for HiPath 3000 Series
Page 1252: ......