Installation
4-146
Service Manual
Installing modules
4.7.3.2
On the HiPath 1150
Installation Procedures
Step
Procedure
1.
Remove the power supply.
2.
Remove the backplane.
3.
Insert the module into one of the slots shown in figure 4-17.
4.
Connect to the module’s MDF Connectors (see Figure 4-40).
5.
Reassemble the entire set.
6.
“Performing a visual inspection” on page 4-189.
7.
Turn on the power supply.
8.
Configure the required data (see “Operation” on page 7-278).
9.
*
*
This is necessary only if you have changed the type of the modules installed in your system.
Using Manager application go to: Advanced tab, > PBX Information tab, > Slot
Allocation tab;
Select the Clear All Slots checkbox;
Update the HiPath System;
Reset the HiPath System.
Summary of Contents for HiPath 1100
Page 1: ...HiPath 1100 HiPath 1120 HiPath 1150 HiPath 1190 Service Manual ...
Page 14: ...Figures 14 Service Manual ...
Page 124: ...Modules 3 124 Service Manual Interconnect cables ...
Page 190: ...Installation 4 190 Service Manual Performing a visual inspection ...
Page 323: ...Service Manual 7 323 Operation Driver Installation Figure 7 44 Windows 2000 Driver location ...
Page 368: ...Operation 7 368 Service Manual HiPath 1100 applications ...
Page 384: ...Abbreviations 9 384 Service Manual ...
Page 388: ...388 Service Manual ...