S2 access
The TME1 coax cable is used for connecting to the S2 interface with an NT modem. If there is
a different impedance between the module and the modem, you must use the Balun.
TME1 coax cable signals
Table 3-45
TME1 coax cable signals
Balun
You must use the balun on the TME1 coax cable if there is any impedance differential between
the TME1 and the NT1 modules.
Technical Data
Pin
Connector
Signal
RX
J1
Receive Data
TX
J2
Transmit Data
Speed
up to 2,048 Mbps
Insulation
100V
Connectors
Coaxial (Interface A): Dual BNC F(RG 59)
Twister - pair (Interface B): 8 - pin shielded RJ 45