en
Installation instructions
30
23.2 Appliance dimensions
You will find the dimensions of the appliance here
23.3 Installation below a worktop
Observe the installation dimensions and the installation
instructions when installing below a worktop.
¡
To ventilate the appliance, the intermediate floor
must have a ventilation cut-out.
¡
The worktop must be secured to the built-in unit.
¡
Observe any available installation instructions for the
hob.
23.4 Installation underneath a hob
If the appliance is installed under a hob, the following
minimum dimensions must be adhered to (including
substructure, if applicable).
The minimum worktop thickness a is based on the
required minimum clearance .
Hob type
a raised in mm
a flush in mm
b in mm
Induction hob
37
38
5
Full-surface induction hob
47
48
5
Gas hob
27
38
5
Electric hob
27
30
2