MENU MAPS
_________________________________________________________________________________________________________
10-25
SIG-00-22-02 JUNE 2022 (Revised September 2022)
Version : B.1
Figure 10-21 Logic: AND 1 XR Enable Used
10.1.4.2 Logic: Features
The GCE MCF provides various logic capability features. Figure 10-22 shows the selection of
these features.
•
ANDs Used controls whether the Logic: AND 2- 8 menu options are available
•
ORs Used controls whether the Logic: OR 1 - 4 menu options are available
•
Equations Used controls whether the Logic: Equation 1-10 menu options are available
•
User Timer controls whether the Logic: User Timers menu options are available and
whether the User Timer 1-10 options show up in the
System Inputs, System Output
and
System I/O
list.
•
Switch Inputs Used controls whether the NWP 1-4 and RWP 1-4 options show up in the
System Inputs
, Output and I/O list.
•
General I/O Used controls whether the General IP 1 – 16 and General OP 1- 8 option
show up in the
System Inputs, System Output
and
System I/O
list.
•
Maint Call Rpt I/O Used controls whether the Maint Call Rpt IP and Maint Call OP show
up in
System Inputs, System Output
and
System I/O
list. The Maint Call OP repeats the
state of the Maintenance call output on the chassis. The Maint Call Rpt IP provides a