42
FLUDEX 4612 en
Operating instructions 10/2017
9.3.1
Possible faults when selecting the coupling and/or coupling size
─
Important information for describing the drive and the environment are not communicated.
─
System power too high.
─
System speed too high or too low.
─
Starting frequency too high.
─
The ventilation of the coupling is inadequate.
─
Chemically aggressive environment is not being taken into consideration.
─
The ambient temperature is not permissible. Observe section 5.
─
Machining of a finished bore with incorrect diameter and/or incorrect fit assignment (see section 6 and
orderreleated title page).
─
The transmission capacity of the shafthub connection is not appropriate to the operating conditions.
9.3.2
Possible faults when fitting the coupling
─
Components with transport or other damage are being fitted.
─
When fitting coupling parts in a heated condition, already fitted NEUPEX flexible elements (12) are
being excessively heated.
─
When attaching the main coupling to the hubcarrier part (120), the Orings (117, 138) are not fitted.
─
The shaft diameter is beyond the specified tolerance range.
─
Coupling sides are being interchanged, i.e. their assignment to the specified drive direction is incorrect.
─
Specified axial fixtures are not fitted.
─
Specified tightening torques are not being adhered to.
─
Alignment / shaftmisalignment values do not match the operating instructions.
─
An incorrect operating fluid and/or an incorrect quantity of operating fluid is being put in.
─
The coupled machines are not correctly fastened to the foundation, and as a result shifting of the
machines e.g. through loosening of the foundation screw connection is causing excessive
displacement of the coupling parts.
─
NEUPEX flexible elements (12) are being omitted or incorrectly positioned.
─
The coupling safeguard does not comply with the guidelines to be applied. It considerably restricts
ventilation of the coupling.
─
Operating conditions are being changed without authorisation.
─
Components are being fitted to the coupling which transmit excessive axial forces or bending moments
to the coupling.
─
Addon parts are not designed in compliance with the Directive 2014/34/EU and are an explosion
hazard.