2BStructure and function
18BFeatures of the 'Technical Ambient Supervision Message'
3
27 | 138
Building Technologies
007004_t_en_--
Fire Safety
2015-11-04
3.3
Features of the 'Technical Ambient Supervision
Message'
The 'Technical Ambient Supervision Message' cannot be configured on all fire
control panels. Observe the information in the 'List of compatibility'.
'Technical Ambient Supervision Message' mode detects an increase in
temperature caused by hysteresis above a specified threshold.
Temperature monitoring compares the current measured temperature with a preset
threshold value.
You can configure the following parameters for the point detector:
●
Threshold value for temperature
●
Alarming when the temperature threshold value is exceeded or undershot
●
Hysteresis range
Parameter configuration is carried out using the 'SintesoWorks' software.
Figure 3: Signal processing by the 'Technical Ambient Supervision Message'
NOTICE
The system is not controlled as laid down in EN 54-2
Infringement of the EN 54-2 standard
●
According to EN 54-2, signals for temperature detection must not be used to
control fire detection equipment.
See also
Point detectors with 'Technical Ambient Supervision
°C
T [°C]
t
Warning level for
Technical Ambient
Supervision Alarm
Result
Signal analysis
Sensory
Algorithms
Environment:
Temperature