
Liquids of fluid group 1
• Pipelines according to Article 4 (a) (ii) First dash
I
II
III
Article 3
Paragraph 3
0,1
1
10
100
1000
10000
25
DN
PS = 0,5
PS = 10
PS = 500
4000
1
10
100
1000
0,5
PS [bar]
D
N
=
2
5
PS
· D
N
=
20
00
500
Figure 11-3
Diagram 3
Liquids of fluid group 2
• Pipelines according to Article 4 (a) (ii) Second dash
I
II
Article 3
Paragraph 3
0,1
1
10
100
1000
10000
DN
PS = 0,5
PS = 10
PS = 500
200
1
10
100
1000
0,5
PS [bar]
D
N
=
2
0
0
PS
· D
N
=5
00
0
500
Figure 11-4
Diagram 4
11.14
Pressure - temperature ratings
Pressure - temperature ratings are determined by process connection material and applicable
standards. The tables below detail the allowed maximum process pressure for sensor variants
with stainless steel and Hastelloy measuring tubes.
With two major exceptions, the pressure rating of the flow sensors is independent of the process
medium temperature. Design rules for flange connections in both the EN1092-1 and ASME
B16.5 standards dictate pressure derating with increasing temperature. The charts below show
the effect of process medium temperature on the pressure ratings for the flanges within the
product program.
Technical data
11.14 Pressure - temperature ratings
SITRANS MASS 2100 & FC300 (FCT010/DSL)
122
Operating Instructions, 06/2020, A5E39788682-AB