Fault
Cause and troubleshooting
/
The operating voltage is incorrect and outside of the normal operating range.
▶
Contact your energy supplier.
The hob is not connected correctly.
▶
Disconnect the hob from the mains. Connect the hob in accordance with the circuit dia-
gram.
The cooking zones
do not heat up, and
is displayed.
Demo mode is activated.
1.
Disconnect the hob from the mains and, after a few seconds, reconnect it.
2.
Deactivate demo mode in the basic settings within the next three minutes.
25.3 Normal noises from your appliance
An induction hob may sometimes cause noises or vi-
brations, such as buzzing, crackling, hissing noises, fan
noises or rhythmic noises.
26 Disposal
26.1 Disposing of old appliance
Valuable raw materials can be reused by recycling.
1.
Unplug the appliance from the mains.
2.
Cut through the power cord.
3.
Dispose of the appliance in an environmentally
friendly manner.
Information about current disposal methods are
available from your specialist dealer or local author-
ity.
This appliance is labelled in accord-
ance with European Directive
2012/19/EU concerning used elec-
trical and electronic appliances
(waste electrical and electronic equip-
ment - WEEE).
The guideline determines the frame-
work for the return and recycling of
used appliances as applicable
throughout the EU.
27 Declaration of Conformity
BSH Hausgeräte GmbH hereby declares that the appli-
ance with Home Connect functionality conforms to the
basic requirements and other relevant provisions of Dir-
ective 2014/53/EU.
A detailed RED Declaration of Conformity can be found
online at siemens-home.bsh-group.com among the ad-
ditional documents on the product page for your appli-
ance.
Hereby, BSH Hausgeräte GmbH declares that the ap-
pliance with Home Connect functionality is in compli-
ance with relevant statutory requirements.
1
A detailed Declaration of Conformity can be found on-
line at siemens-home.bsh-group.com/uk/ among the
additional documents on the product page for your
appliance.
1
Only applies to Great Britain
2.4 GHz band (2400–2483.5 MHz): Max. 100 mW
5 GHz band (5150–5350 MHz + 5470–5725 MHz):
Max. 100 mW
BE
BG
CZ
DK
DE
EE
IE
EL
ES
FR
HR
IT
CY
LI
LV
LT
LU
HU
MT
NL
AT
PL
PT
RO
SI
SK
FI
SE
NO
CH
TR
IS
UK (NI)
5 GHz WLAN (Wi-Fi): For indoor use only.
AL
BA
MD
ME
MK
RS
UK
UA
5 GHz WLAN (Wi-Fi): For indoor use only.
1
Only applies to Great Britain