Total Cell Losses
The table below lists the no load losses (constant regardless of output) and load losses at maximum output power
using primary source components, at rated 750Vrms input. The values shown are the cell TOTAL losses versus
output current.
Total Cell Losses vs Output Current
250
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
0
20
40
60
80
100 120 140 160 180 200 220 240 260 280 300
Output Current, Arms
Los
ses
, W
att
s
40A
70A
100A
140A
200A
260A
Iout
40A
70A
100A
140A
200A
260A
25
273
268
268
244
241
248
50
470
450
436
378
371
379
75
726
680
637
536
524
527
100
1,042
960
873
720
700
692
125
1,416
1,288
1,142
929
900
875
150
1,850
1,665
1,445
1,163
1,124
1,076
175
1,783
1,421
1,371
1,294
200
2,154
1,705
1,642
1,529
225
2,014
1,936
1,782
250
2,347
2,254
2,053
275
2,706
2,595
2,341
300
3,090
2,960
2,646
325
3,348
2,970
350
3,760
3,310
375
4,196
3,668
400
4,655
4,044
425
5,137
4,437
450
5,643
4,848
475
6,173
5,276
Summary of Contents for Eupec
Page 16: ...Cell Overview MicroHarmony Cell Sizes 40 260A Manual 1 6 19001467 Version 1 0 s 1 ...
Page 36: ...Installation MicroHarmony Cell Sizes 40 260A Manual 3 4 19001467 Version 1 0 s 3 ...
Page 42: ...Electrical Description MicroHarmony Cell Sizes 40 260A Manual 4 6 19001467 Version 1 0 s 4 ...
Page 56: ...Repair Hints MicroHarmony Cell Sizes 40 260A Manual 8 4 19001467 Version 1 0 s 8 ...
Page 76: ...Drive Calc Express MicroHarmony Cell Sizes 40 260A Manual 10 2 19001467 Version 1 0 s 10 ...
Page 86: ...Communication Protocol MicroHarmony Cell Sizes 40 260A Manual 11 10 19001467 Version 1 0 s 11 ...
Page 87: ...MicroHarmony Cell Sizes 40 260A Manual NOTES 19001467 Version 1 0 N 1 s NOTES ...
Page 88: ...NOTES MicroHarmony Cell Sizes 40 260A Manual N 2 19001467 Version 1 0 s ...
Page 89: ...MicroHarmony Cell Sizes 40 260A Manual NOTES 19001467 Version 1 0 N 3 s ...
Page 90: ...NOTES MicroHarmony Cell Sizes 40 260A Manual N 4 19001467 Version 1 0 s ...