background image

 

GAMMA 

instabus

 

Technical Product Information 

March 2008 

DELTA profil 

Display and control unit 

UP 585 

5WG1 585-2AB_1 

DELTA style 

Display and control unit 

UP 584 

5WG1 584-2AB_1 

DELTA ambiente 

Display and control unit 

UP 586 

5WG1 586-2AB_1 

Siemens AG 

UP 58x, 6 pages 

Technical Manual 

Automation and Drives Group 

 

 

Electrical Installation Technology 

©

 Siemens AG 2008 

Update: http://www.siemens.com/gamma 

P.O. Box 10 09 53, D-93009 Regensburg  

Subject to change without prior notice 

 

 

2.3.1.2/1 

 

 

 

 

 

Product 

DELTA profil 

DELTA style 

DELTA ambiente 

 
Display and control 
unit

 

5WG1 585-2AB01  pearl grey 
5WG1 585-2AB11  titanium white 
5WG1 585-2AB21  anthracite 
5WG1 585-2AB71  silver 

5WG1 585-2AB11  titanium white 
5WG1 584-2AB21  basalt black 
5WG1 584-2AB41  platinum metallic 

5WG1 586-2AB01  arctic white 

ordered separately from the DELTA ranges 

Frames 

cut out frames 

--- 

--- 

Intermediate frames 

--- 

5TG1 328      titanium white 
5TG1 368      basalt black 
5TG1 328-1  platinum metallic 

--- 

 

 

 

Diagram 1: Installation of the display unit 

 

 
 
 
B1  Driver with bus connection  *) 
B2 Frame 
B3 Intermediate frame (only for DELTA style) 
B4  Display unit  *) 
B5  Fixing screw  *) 
B6  Blende  *) 
 
*) Lieferumfang 
 
 
 

 
 

Product and Applications Description 

 
The display unit is used to indicate freely programmable 
messages. A message generally consists of read-only 
text and placeholders.  
The display unit can be freely configured with different 
fonts, characters and symbols. Depending on the pa-
rameter settings, it is possible to assign alarm functions 
to the messages. The display is carried out via a graphi-
cal LC display. If Arial font is used in 12 pt, 5 lines can be 
displayed. The LC display contains green/yellow back-
lighting which can be switched on and off via software. 
The output of an alarm tone can also be set. 

The various messages can be selected by pressing the 
two push buttons on the display unit. It is also possible 
to operate selectable bus functions with two further 
push buttons. 
The display unit is placed on the bus driver module 
together with the relevant frame. It can only function in 
connection with this bus driver module and an appro-
priate application program i.e. the display unit consists 
of the device [hardware] and the application program 
[software]. 
The frames are not included with supply and must be 
ordered separately. The intermediate frame should be 
used for DELTA style. 

B1

B2

 

B3

 

B4

 

B5

 

B6

 

Summary of Contents for Delta Series

Page 1: ...yle B4 Display unit B5 Fixing screw B6 Blende Lieferumfang Product and Applications Description The display unit is used to indicate freely programmable messages A message generally consists of read only text and placeholders The display unit can be freely configured with different fonts characters and symbols Depending on the pa rameter settings it is possible to assign alarm functions to the mes...

Page 2: ...NGER The device may only be installed and commissioned by an authorized electrician The device may not be inserted in the same box as 230 V devices The device may be used in switch sockets if VDE approved devices have been used The prevailing safety and accident regulations must be observed The device may not be opened For planning and construction of electric installations the relevant guidelines...

Page 3: ... of failure 572 fit Markings KNX EIB CE mark In accordance with the EMC guideline residential and functional buildings and the low voltage guideline Location and function of the operating ele ments Diagram 2 Location of the display and operating ele ments A1 LC display LCD for indicating the messages A2 Push buttons for scrolling through the lines UP DOWN A3 Push buttons for controlling the select...

Page 4: ...xing the display unit onto the driver B1 B6 Cover Place the display unit B4 with B6 and the relevant frame B2 onto the driver B1 Remove the cover B6 from the display unit as de scribed under Dismantling in order to program the physical address Secure the display unit B4 with the two screws B5 Now program the physical address The location of the programming button and the pro gramming LED is indica...

Page 5: ...iver at the opening and lift the top of the cover for wards with the screwdriver Diagram 6b Variant 2 Diagram 6c Removing the protective film Removing inserting the bus terminal Diagram 7 To remove the bus terminal carefully insert the screwdriver in the wire entry slot in the grey section of the bus terminal D2 2 and pull the bus terminal D2 out of the driver D1 To insert the bus terminal place t...

Page 6: ...mma Siemens AG 2008 Electrical Installation Technology Subject to change without prior notice P O Box 10 09 53 D 93009 Regensburg 2 3 1 2 6 Dimension Driver Dimensions in mm Dimension Display unit Dimensions in mm General Notes The operating instructions must be handed over to the client Any faulty device should be returned to the local Siemens office If you have further questions concerning the p...

Reviews: