F
unction
d
iagr
am
s
Ve
ct
or
co
nt
ro
l
2-
52
2
© Sie
m
ens AG 2009 All Righ
ts R
eser
ved
SINAMICS
G120
Con
trol
U
nits C
U
230P-2
P
ar
ameter
M
anual (LH9)
, 11/2009
Fi
g.
2
-7
4
605
0 – Kp
_n/Tn
_n ad
aption
- 6050 -
Function diagram
8
7
6
5
4
3
2
1
FP_6050_97_51.vsd
Vector control
G120 CU230P-2
29.10.2009
V4.3
Kp_n/Tn_n adaption
[6040.8]
Tn_n_adapt
y
x
[6040.8]
Tn
Kp
n
Kp
Kp_n_adapt
x
n
n
Tn
n
Kp_n_basic
Tn_n_basic
1
1
0
<1>
<1>
<1>
<1>
<1>
[6490.7]
Free Kp_n adaptation
Speed-dependent Kp_n/Tn_n adaptation
If the lower transition point exceeds the upper transition point, the Kp-adaptation also changes over.
Free Tn adaptation active (p1400.6)
To the speed controller
[6040.4]
Adapt_factor upper
0.0 ... 200000.0 [%]
p1459 [D] (100.0)
n_ctrl AdaptKpLow
0.00 ... 400.00 [%]
p1456 [D] (0.00)
n_ctrl AdaptKp up
0.00 ... 400.00 [%]
p1457 [D] (0.00)
n_ctrl Adpt_sig Kp
(0)
p1455 [C]
n_ctrl Kp scal
(1)
p1466 [C]
r0063
n_act [1/min]
[0]
n_ctrl Kp n upper
0.0 ... 200000.0 [%]
p1461 [D] (100.0)
n_ctrl Tn n upper
0.0 ... 200000.0 [%]
p1463 [D] (100.0)
n_ctrl n upper
0.00 ... 210000.00 [1/min]
p1465 [D] (210000.00)
n_ctrl n lower
0.00 ... 210000.00 [1/min]
p1464 [D] (0.00)
To the speed controller
[6040.4]
Adapt_factor lower
0.0 ... 200000.0 [%]
p1458 [D] (100.0)