Function diagram
8
7
6
5
4
3
2
1
FP_9220_97_52.vsd
CANopen
G120 CU230P-2 CAN
29.10.2009
V4.3
Control word, CANopen
STW1.0
STW1.1
STW1.2
STW1.3
STW1.4
STW1.5
STW1.6
STW1.8
STW1.9
STW1.11
STW1.12
STW1.13
STW1.14
STW1.15
STW1.7
STW1.10
p0848[0] = r2090.2
p0852[0] = r2090.3
-
-
-
p2103[0] = r2090.7
-
-
-
pxxxx[y] = r2090.11
pxxxx[y] = r2090.12
pxxxx[y] = r2090.13
pxxxx[y] = r2090.14
pxxxx[y] = r2090.15
p0840[0] = r2090.0
p0844[0] = r2090.1
[2501.3]
[2501.3]
-
-
-
[2546.1]
-
-
-
-
-
-
-
-
[2501.3]
[2501.3]
-
-
-
-
-
[8060]
-
-
-
-
-
-
-
-
-
<1>
<1>
-
Signal targets for control word CANopen (r8795)
Signal
= ON (pulses can be enabled)
Interconnection
parameters
[Function diagram]
internal control word
[Function diagram]
signal target
0 = OFF1 (braking with RFG, then pulse cancellation and ready-to-power-up)
1 = No coast-down activated (enable possible)
0 = Activate coast-down (immediate pulse cancellation and power-on inhibit)
1 = No fast stop activated (enable possible)
0 = Activate fast stop (OFF3 ramp p1135, then pulse cancellation and power-on inhibit)
1 = Enable operation (pulses can be enabled)
0 = Inhibit operation (cancel pulses)
Reserved
Reserved
Reserved
= Acknowledge fault
Reserved
Reserved
Reserved
Can be freely connected
Can be freely connected
Can be freely connected
Can be freely connected
Can be freely connected
Depending on the position of the CANopen control word in p8750, the number of the binector to be connected changes.
Meaning