SINAMICS
G120 Contr
ol
U
nits CU
230P-2
Par
ameter
M
an
ual (
LH9), 11/2009
Fi
g. 2
-4
103
0
–
Hand
ling
BICO techn
olog
y
- 1030 -
Function diagram
8
7
6
5
4
3
2
1
FP_1030_97_51.vsd
Explanations for the function diagrams
G120 CU230P-2
29.10.2009
V4.3
Handling BICO technology
r0723.15
r0723
r0722.0
1
2
722.0
p1055[C]
Kl.5
r0967.8
[2220]
[2501]
[3020]
r1050
[3030]
2
1
p1055[0] = 722.0
p1070[0] = 1050
Main setpoint
(755[0])
p1070.[C]
Handling BICO technology
Binector:
Connector:
Raise
Connectors are "analog signals" that can be freely interconnected (e.g. percentage variables, speeds or torques).
Connectors are also "CO:" display parameters (CO = Connector Output).
Parameterization:
At the signal destination, the required binector or connector is selected using appropriate parameters:
"BI:" parameter for binectors (BI = Binector Input)
or
"CI:" parameter for connectors (CI = Connector Input)
Example:
The main setpoint for the speed controller (CI: p1070) should be received from the output of the motorized potentiometer
(CO: r1050) and the "jog" command (BI: p1055) from digital input DI0 (BO: r0722.0, Terminal 5 (Kl.5)) on the CU230.
Control bit 8
Digital input
DI0
Setpoint
channel
Motorized potentiometer
Jog setpoint 1
Speed controller
Parameterizing steps:
Terminal 5 (Kl.5) acts as "Jog bit 0".
The output of the motorized potentiometer acts as main setpoint for the speed controller.
Lower