CR-IR347
Service Manual
PM - 60
009-058-00
10.20.2000 FM2732 (2)
PM - 60
9.
Subscanning Unit and Side-Positioning
Conveyor
9.1
Subscanning Unit (Cleaning the SUS Belt/Rubber Belt/
Kapton
®
Belt)
2Y
At intervals of two years, or when 120,000 IPs have been processed
→
Clean.
CAUTION
Wear gloves when cleaning the belts.
REFERENCE
Remove/install the rubber belt while rotating the driving shaft.
■
SUS and Rubber Belts
Tension coil spring
[Remove] BR4x8 (x2)
Transparent
cover
FR7H6140.EPS
FRONT
Rubber belt
[Clean]
Moistened cloth
SUS belt
[Clean]
Cloth (ethanol)
Rubber belt
SUS belt
Driving
shaft
2Y
2Y