4 Mode of Operation
4.2 PLC data types
HCS4x00Library
Entry ID: 109478117, V2.2.1, 09/2018
33
S
ie
m
e
n
s
A
G
2018
A
ll r
ig
h
ts
r
e
s
e
rv
e
d
4.2.42
"LHcs4x00_typeDiagDataCim"
The “LHcs4x00_typeDiagDataCim” PLC data type includes die diagnostic data of
the CIM or the PM.
Table 4-42
Name
Data type
Description
slotNumber
Byte
Slot number of the faulty module
subSlotNumber
Byte
Slot number of the faulty sub-module
fault
Bool
Fault occurred
errorCount
Int
Number of active errors
errorCode
Array[1..10] of Word
Array with error IDs
4.2.43
"LHcs4x00_typeDiagDataPom"
The “LHcs4x00_typeDiagDataPom“ PLC data type includes the diagnostic data of
a POM.
Table 4-43
Name
Data type
Description
fault
Bool
Fault occurred
errorCount
Int
Number of active errors
errorCode
Array[1..10] of Word
Array with error IDs
channel
Array[1..16] of
"LHcs4x00_typeDiagDataChannel"
Array with error information on the power output
channels
4.2.44
"LHcs4x00_typeDiagDataChannel"
The “LHcs4x00_typeDiagDataChannel” PLC data type includes the diagnostic data
of a power output channel.
Table 4-44
Name
Data type
Description
fault
Bool
Fault occurred
errorCode
Word
Error ID