s
Operating manual
36
Temperature data format
two-colour/ratio Lambda 1
– Lambda 2
(one cycle):
Byte Negative Temperature Positive Temperature Temperature exceeds
measuring range
Temperature falls below
measuring range
1
Space
Space
Space
Space
2
Minus symbol -
Space
Minus symbol -
Minus symbol -
3
Digit 1000
Digit 1000
O
U
4
Digit 100
Digit 100
V
N
5
Digit 10
Digit 10
E
D
6
Digit 1
Digit 1
R
E
7
Decimal point .
Decimal point .
Space
R
8
Decimal place
Decimal place
Space
Space
9
Space
Space
Minus symbol -
Minus symbol -
10
Unit C or F
Unit C or F
Space
Space
11
Tabulator
Tabulator
Tabulator
Tabulator
12
Space
Space
Space
Space
13
Minuszeichen -
Space
Minus symbol -
Minus symbol -
14
Digit 1000
Digit 1000
O
U
15
Digit 100
Digit 100
V
N
16
Digit 10
Digit 10
E
D
17
Digit 1
Digit 1
R
E
18
Decimal point .
Decimal point .
Space
R
19
Decimal place
Decimal place
Space
Space
20
Space
Space
Minus symbol -
Minus symbol -
21
Unit C or F
Unit C or F
Space
Space
22
Tabulator
Tabulator
Tabulator
Tabulator
23
Space
Space
Space
Space
24
Minuszeichen -
Space
Minus symbol -
Minus symbol -
25
Digit 1000
Digit 1000
O
U
26
Digit 100
Digit 100
V
N
27
Digit 10
Digit 10
E
D
28
Digit 1
Digit 1
R
E
29
Decimal point .
Decimal point .
Space
R
30
Decimal place
Decimal place
Space
Space
31
Space
Space
Minus symbol -
Minus symbol -
32
Unit C or F
Unit C or F
Space
Space
33
Carriage Return
Carriage Return
Carriage Return
Carriage Return
The cycle time in which the temperature reading is transmitted can be
set via parameter
ACYC
(minimum cycle duration is 0.1 second).
19.4 User Recalibration
If ever required, the pyrometer can be recalibrated. Go to Submenu Cali-
bration. Press command „K“ and then enter the password „100“ to ac-
cess the calibration menu.
All signs/symbols are ASCII coded; preceding zeros will be
transmitted
Summary of Contents for Ardoptix PT 140 AF1
Page 1: ...Two colour Pyrometer PT 14x 7MC3040 Operating Manual 03 2017 ...
Page 2: ......
Page 3: ...Two colour Pyrometer PT Ident Nr 106 7393 PT14x_si_en doc Stand 21 03 2017 830 hm 810 het ...
Page 8: ...s Operating manual ...
Page 56: ...s Operating manual 48 29 Dimensions ...
Page 63: ...s Operating manual 55 ...
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......