Appendi x A Technical Des cription
Instructions for Use
A - 9
Continuous Wave Doppler (Auxiliary CW)
(Requires the Cardiac Application Module option or the Continuous Wave Doppler Interchangeability
Option)
Activates the port for Continuous Wave Doppler (pencil) transducers
Color Doppler Velocity (CDV) Features
2D/Color display
User-adjustable color region of interest (ROI), size, and position
Independent controls for color gain, PRF, invert, baseline, space/time, persistence, priority,
and smoothing
Up to four user-selectable transmit frequencies
Color On/Off invert and baseline shift functions
Three user-selectable color flow states: low, general, and high
Color-adaptive wall filter
PRF range of 100 Hz to 19,500 Hz
Six color velocity maps (three velocity maps and three ve variance maps (VV))
Up to 512 color samples per color data line
Up to 512 2D-mode lines plus 256 color lines
Color Doppler Energy (CDE) Features
Power mode On/Off control
Background Power Doppler on and off selection
Power Gain from -20 dB to 20 dB in one decibel increments
Independent controls for power gain, PRF, invert, baseline, resolution/frame rate,
persistence, priority, and smoothing
Up to four user-selectable transmit frequencies
Up to eight user-selectable Power map selections
Up to five persistence levels (0 to 4)
Up to four levels of Power smoothing (0 to 3)
PRF range from 100 Hz to 19,500 Hz
Adaptive wall filter
Three user-selectable flow states: low, general, high
Summary of Contents for Acuson S2000
Page 12: ...1 Introduction 1 2 Instructions for Use ...
Page 14: ...1 Introduction 1 4 Instructions for Use System Review Example of the ultrasound system ...
Page 84: ...2 Safety and Care 2 54 Instructions for Use ...
Page 86: ...3 System Setup 3 2 Instructions for Use ...
Page 112: ...3 System Setup 3 28 Instructions for Use ...
Page 114: ...4 Examination Fundamentals 4 2 Instructions for Use ...
Page 144: ...5 Transducer Accessories and Biopsy 5 2 Instructions for Use ...
Page 196: ...7 Specialty Transducers 7 2 Instructions for Use ...
Page 200: ...7 Specialty Transducers 7 6 Instructions for Use ...
Page 202: ...8 Physiologic Function 8 2 Instructions for Use ...
Page 208: ...9 eSieFusion Imaging 9 2 Instructions for Use ...
Page 236: ...10 Virtual Touch Applications 10 2 Instructions for Use ...
Page 258: ...10 Virtual Touch Applications 10 24 Instructions for Use ...
Page 302: ...Appendix A Technical Description A 44 Instructions for Use ...
Page 326: ...Appendix B Control Panel and Touch Screen B 24 Instructions for Use ...
Page 328: ...Appendix C Control Panel C 2 Instructions for Use ...
Page 394: ...Appendix D On screen Controls D 50 Instructions for Use ...
Page 444: ...Appendix F Acoustic Output Reference F 2 Instructions for Use ...
Page 516: ...Appendix F Acoustic Output Reference F 74 Instructions for Use ...
Page 517: ......
Page 518: ......