27.04.2006
5.3 Storage
Conditions
The conditions stated below are only valid for modules in their original packed state in
weather protected, non-temperature-controlled storage locations. Normal storage time under
these conditions is 12 months maximum.
Table 24: Storage conditions
Type
Condition
Unit
Reference
Air temperature:
Low
High
-40
+85
°C
ETS 300 019-2-1: T1.2, IEC 68-2-1 Ab
ETS 300 019-2-1: T1.2, IEC 68-2-2 Bb
Humidity relative: Low
High
Condens.
10
90 at 30°C
90-100 at 30°C
% ---
ETS 300 019-2-1: T1.2, IEC 68-2-56 Cb
ETS 300 019-2-1: T1.2, IEC 68-2-30 Db
Air pressure:
Low
High
70
106
kPa
IEC TR 60271-3-1: 1K4
IEC TR 60271-3-1: 1K4
Movement of surrounding air
1.0
m/s
IEC TR 60271-3-1: 1K4
Water: rain, dripping, icing and
frosting
Not allowed
---
---
Radiation: Solar
Heat
1120
600
W/m
2
ETS 300 019-2-1: T1.2, IEC 68-2-2 Bb
ETS 300 019-2-1: T1.2, IEC 68-2-2 Bb
Chemically active substances
Not
recommended
IEC TR 60271-3-1: 1C1L
Mechanically active substances
Not
recommended
IEC TR 60271-3-1: 1S1
Vibration sinusoidal:
Displacement
Acceleration
Frequency
range
1.5
5
2-9 9-200
mm
m/s
2
Hz
IEC TR 60271-3-1: 1M2
Shocks:
Shock
spectrum
Duration
Acceleration
semi-sinusoidal
1
50
ms
m/s
2
IEC 68-2-27 Ea